background image

dormakaba TS93 GSR/EMF T 1A, 1I, 2 Installation Instructions

08280031

08-2019

TS93 GSR Surface Applied Closers

4

Surface closer system

Handing the door

Fig.1 

 

Hinge

Hinge

Exterior side of door

Interior side of door

Left hand door (LH)

Right hand door (RH)

The surface closer is comprised of the following components.

1. 

Closer body: “B” body

2. 

Main arm

3. 

Active track assembly

4. 

Inactive track assembly

5. 

Pinion

6. 

Track covers and center cover

7. 

Closer cover

8. 

Closer end caps

9. 

Connecting channel

1.5  Handing the door

Fig.2 

1.4  Surface closer system

1

5

7

8

6

3/4

3/4

6

9

2

2

Summary of Contents for TS93 GSR T Series

Page 1: ...TS93 GSR EMF T 1A 1I 2 Surface Applied Closer Pull side track mount and coordinator system Installation instructions 08280031 08 2019 EN ...

Page 2: ...r 4 2 Installation instructions 5 2 1 Installing the back plate 5 2 2 Installing the surface closer 5 2 3 Installing the slide channel 6 2 4 Installing the main arm 6 2 5 Secure main arm 7 2 6 Installing the coordinator system 7 2 7 Installing conduit for EMF 8 2 8 Installing coordinator system continued 8 2 9 Wiring the EMF 9 3 Adjustments 10 3 1 Adjust closing speeds sweep latch backcheck delaye...

Page 3: ...1 10 32 tap 2 Phillips screwdriver M2 hex key Wood 1 8 3 16 flat head screwdriver 1 2 Size selection chart 1 3 Tools recommended GSR EMF T 1I Active door inactive door holds open together The GSR EMF T 1I incorporates an electric hold open mechanism in the inactive leaf The coordinator mechanism tied to the inactive leaf in turn holds the active leaf at whatever degree of opening it is placed Both...

Page 4: ... of door Interior side of door Left hand door LH Right hand door RH The surface closer is comprised of the following components 1 Closer body B body 2 Main arm 3 Active track assembly 4 Inactive track assembly 5 Pinion 6 Track covers and center cover 7 Closer cover 8 Closer end caps 9 Connecting channel 1 5 Handing the door Fig 2 1 4 Surface closer system 1 5 7 8 6 3 4 3 4 6 9 2 2 ...

Page 5: ...ecure closer body to plate Use four M5 x 47mm screws for each closer NOTE Use ONLY hand Phillips bit driver 2 or Pozidriv PZ 2 2 2 Installing the surface closer Fig 4 Fig 3 2 1 1 Secure plate to door Use four 10 32 x 5 8 PH screws 10 x 1 1 2 wood screws provided for each plate NOTE Ensure arrows point in direction of arm location Left hand door Right hand door Backplate 10 32x5 8 Toward the hinge ...

Page 6: ...s flat head driver 2 3 3 Insert end caps into track 2 3 4 Secure end of track through end caps Use two 10 32x2 FH screws 2 3 5 Slide end cap covers onto end caps 2 3 Installing the slide channel Fig 5 2 4 1 Attach 1 2 wrench to bottom pinion 2 4 2 While looking up rotate pinion square until it aligns to square hole on arm LH turn 5 counter clockwise RH turn 5 clockwise Right hand door Inactive Lef...

Page 7: ...reely If locking pin falls out discard after completing installation Arm Slide shoe Arm M8x15 SH bolt Left hand door Active Right hand door Inactive Trigger dial 2 6 Installing the coordinator system Fig 8 2 6 1 Close both door leafs 2 6 2 Push plastic guide element up against slide shoe 2 6 3 Fully wind trigger dial towards door frame 2 6 4 Align connecting channel with trigger dial per image abo...

Page 8: ...rdinator system continued Fig 10 Left hand door Active Right hand door Inactive Clamping rod Trigger dial Connecting channel Set screw Locking pin Plastic guide Connecting channel Clamping plate Trigger dial 2 8 1 Open active leaf to retract clamping rod 2 8 2 Active door Insert connecting channel into trigger dial 2 8 3 Inactive door Insert connecting channel into plastic guide 2 8 4 Unwind trigg...

Page 9: ...ss into terminals 1 and 2 active door track of the 6 pin terminal block EMF 1I Plug in wire hardness to terminals 1 and 2 active door track of the 6 pin terminal block EMF 1A No plug in wire harness to 6 pin terminal block of active door NOTE Be sure power is off prior to making following connections 2 9 2 Connect power wire harness to 24 VDC power supply 2 9 3 Plug in power wire harness to termin...

Page 10: ...ld open force Decrease force spin dial away from door frame Increase force spin dial towards door frame NOTE Do not set release force too high Damage may occur to door hinges or GSR system 3 2 Adjust optional hold open Increase Decrease Decrease Increase Backcheck Delayed action Sweep Latch Speed 3 1 1 Adjust the closing sweep speed for the area from 70 to start of latch Increase sweep speed Turn ...

Page 11: ... the door TS9356 NOTE Supplied with a size 6 spring setting Increase force turn clockwise 6 times max Regular Mount Pull side closers Closer size Max door weight lbs Door width Full turns Interior Exterior TS9315 2 100 2 6 5 3 125 3 2 6 9 4 150 3 6 3 14 5 200 4 3 6 18 TS9356 5 200 4 3 6 4 6 250 4 6 4 0 4 Install covers 4 1 1 Snap both end covers onto closer body end caps 4 1 2 Remove un needed tab...

Page 12: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...