Set Time Delay Values: 

The Delay and Open Periods may be set up at this time or later by the Manager. To set the Time Delay Periods follow the 
instructions below or refer to Manager Instructions 732.018.
1.  Enter Manager combination and 

hold down last digit of combination until lock double signals release and the LED  

stays on

.

2. 

PRESS 9

3. Enter two-digit Delay Period value (00 to 99 minutes) followed by the two-digit Open Period value (00 to 19 minutes).
4. Re-enter the Delay and Open Period values to confirm.

ACTIVATE THE LOCK 

To complete the activation of the lock and freeze the configuration, the Manager combination MUST be changed. Please 
note, SMR must be changed first or it will be lost.

To change the Manager combination, follow the steps below:
CAUTION:  

Always perform this operation with the door open!

1. Enter the default Manager combination and hold down the last digit until unit double signals twice and the LED stays on.
2. 

Press 0

.

3. Enter your NEW combination, 
4. Re-enter your NEW combination to confirm.
5. The lock is now active and the configuration is frozen.
6. Test lock operation several times before closing the door.

NOTE: 

If default combinations are used, it is recommended that they be changed. New combination will not be accepted if 

it varies from the current combination by only one digit (+/-). When selecting a combination, do not use a birthday or other 
predictable information that could give correlation between the user and the combination.

RESET THE LOCK

(Reset Box [P/N 6066] required.)
To change the lock settings after the configuration is frozen, you must reset the lock.
1. Remove battery.
2. Hold down the 

0

 key for at least 10 seconds to discharge all internal capacitors.

3. Connect Reset Box to BAT port on Lock.
4. 

PRESS 1

   If the lock opens, the factory reset is complete. If the lock does not open, disconnect the Reset Box and repeat steps 2 

and 3.

5.  Disconnect Reset Box.  

The Lock is now in Factory mode, and is ready to be configured by the PC Software or through the keypad.

dormakaba USA Inc.
749 W. Short St.
Lexington KY 40508
T: 859 253 4744
F: 859 255 2655
Toll-free: 877 522 2627

www.dormakaba.us

Summary of Contents for LA GARD ComboGard Pro 39E

Page 1: ...Setup Instructions LA GARD ComboGard Pro 39E Electronic Lock P N 731 018 Rev I 05 2018 ...

Page 2: ...pening override the time delay or enable the remote override depending on the selection programmed for External Signals External Signal disables Lock opening with valid combination OR External Signal overrides Time Delay This option is ONLY available if enabled using Setup software OR External Signal enables the Remote Override This option is ONLY available if enabled using Setup software and with...

Page 3: ...The LED will flash once every second Open Period The LED will flash twice a second and the Entry Device will beep every 10 seconds If any key is pressed the Lock will flash the LED and beep three times Penalty Period The LED will flash every ten 10 seconds Low Battery Warning During a Lock opening the LED will flash and Entry Device will beep repeatedly SUPER MASTER RESET SMR SMR will reset the lo...

Page 4: ... be displayed Figure 1 Figure 1 Select the COM Port When the Setup program is started it identifies the COM Ports that are currently available on your PC You must select the COM Port to be used when communicating with the lock each time you start the program 1 Access the Device Manager to determine which COM Port to select for the Setup Software by completing the following steps a Right click on M...

Page 5: ...is currently installed will follow the device description Figure 2 Figure 2 If using a Serial Adapter identify the standard Serial COM Port to be used Standard Serial COM Ports are identified in the list with a description of Communications Port 2 From the Setup software select the Configuration menu on the Menu bar The list of available COM Ports will be displayed 3 Select the appropriate COM por...

Page 6: ...stalled The software will automatically install User 1 with the default combination 1 1 1 1 1 1 if no other User s are selected for installation Figure 4 Figure 4 Time Delay Override If selected User 9 must be installed to use this option The software will automatically install User 9 without combination Figure 5 The Manager can choose to enable the w Combination option or enroll User 9 through th...

Page 7: ...his option is ONLY available with Lock code level 39E v1 09 or higher Remote Override is typically used by the banking industry and changes how the lock is accessed Input signal to the Alarm Box will enable opening of the lock using only one valid combination If there is no input signal then the lock can be opened by entering two valid combinations WARNING The silent alarm will be activated if the...

Page 8: ...to the lock port marked ENT 2 Connect power to the lock through the Entry Device 9 volt battery or by connecting a LA GARD battery box or AC Power Adapter to the lock port marked BAT 3 Plug the Interface Adapter with the appropriate programming cable into PC 4 Plug the programming cable into the audit programming port of the Entry Device Figure 10 5 Click on the Transmit button in the software Fig...

Page 9: ... Figure 14 SAVE SETUP CONFIGURATION Once the setup configuration has been completed you may name and save the setup file xml for future use 1 Click the Save button or on the Files tab at the top of the program and select Save Figure 15 2 Name the file and click the Save button Figure 16 Figure 15 ...

Page 10: ...d the LED stays on 4 Press 0 5 Enter the NEW combination 6 Re enter the NEW combination to confirm The lock is now active and the configuration is frozen NOTE To change the settings after the configuration has been frozen the lock must first be reset Refer to the Reset Lock section of this document 8 Test unit operation several times before closing the door NOTE If default combinations are used it...

Page 11: ...combination and hold down last digit of combination until lock double signals twice and the LED stays on 2 PRESS 8 3 Enter 0 this maintains current combination length value 4 Enter desired Lock Mode configuration from the chart below 5 Enter 0 and re enter the desired Lock Mode configuration to confirm NOTE Dual Mode cannot be selected if at least one additional User has not been enrolled User 9 m...

Page 12: ...s on 2 Press 0 3 Enter your NEW combination 4 Re enter your NEW combination to confirm 5 The lock is now active and the configuration is frozen 6 Test lock operation several times before closing the door NOTE If default combinations are used it is recommended that they be changed New combination will not be accepted if it varies from the current combination by only one digit When selecting a combi...

Reviews: