6 Commissioning
6.1
Network parameters
Agree on the network parameters of the network, the device and the system software, and
set them.
Overview of the ports
Setting
Designation
Number
•
Server command (TCP)
for data transfer from the device to the sys-
tem software
Standard: 3000
Range: 1–32,767
●
■
•
Terminal command (TCP)
for data transfer from the system software
to the device
Standard: 3001
Range: 1000–32,765
●
■
•
ITM (TCP)
Inter-terminal communication
=
Terminal c1
○
■
•
Network monitoring (TCP)
Network monitoring of units among each
other
=
Terminal c2
○
■
−
•
Telnet (TCP)
Access to service functions via Telnet.
Standard: 23
Range: 1–32,767
◐
■
•
mDNS (UDP)
Multicast DNS
5353 (fix)
◐
■
−
•
DNS (TCP/UDP)
Host name resolution by DNS server
53 (fixed)
○
−
−
•
HTTP/HTTPS (TCP)
You can use a browser to open a configur-
able transaction page via the web server
Standard: 80/443
Range: 1–32,767
○
−
•
SNMP (UDP)
To monitor the LAN interface with SNMP
Standard: 161
Range: 1–161
○
−
−
Setting
Network: Firewall
The required ports must be released and activated.
● required
◐ needed for MATRIX Device Scanner, otherwise optional
○ optional
Device: Supplied state
■ On
− Off
The following ports can be activated/deactivated in the system software.
•