Water connections, Vented
Instruction Manual DR-FC
25
is
3.7
Water connections,
Vented
3.7.1
Cold water side
See
1. Fit an approved stop valve
on the cold water side between the water
and the water heater, as required by regulations. Refer also to
’1.3 Regulations and documents’
3.7.2
Top to bottom recirculating pump
You can connect a top to bottom recirculation pump to prevent stratification of
the water ("stacking")in the water heater.
1. Fit a pipe (Ø 22 mm), a stop valve
and a top to bottom recirculation
pump
2. Fit non-return valve
.
3. Fit stop valves
.
3.7.3
Hot water side
See
n
Remark
Insulating long hot water pipes prevents unnecessary energy loss.
1. Fit the safety valve
2. Optional: fit a temperature gauge
to be able to check the temperature of
the tap water.
3. Fit a stop valve
in the hot water outlet pipe, for use when servicing.
4. If a circulation pipe is to be fitted, then refer to paragraph
3.7.4
Circulation pipe
See
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump
of the correct capacity for the length and resistance
of the circulation system.
2. Fit a non-return valve
a downstream the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves
for service purposes.
4. Connect the circulation pipe to the cold water supply pipe.
3.7.5
Condensation drainage
See paragraph
3.8
Gas connection
Warning
Gas installation may only be carried out by an authorised installer in
compliance with the general regulations imposed by the gas company.
Refer also to paragraph
’1.3 Regulations and documents’
c
Note
Make sure that the diameter and length of the gas supply pipe are large
enough to supply sufficient capacity to the water heater.
Summary of Contents for DR-FC 25
Page 2: ...2...
Page 16: ...Functioning of the water heater 16 Instruction Manual DR FC 2 gis...
Page 42: ...Filling and draining 42 Instruction Manual DR FC 4 gis...
Page 46: ...The control panel 46 Instruction Manual DR FC 5 gis...
Page 50: ...Status of the water heater 50 Instruction Manual DR FC 6 gis...
Page 56: ...Starting up and shutting down 56 Instruction Manual DR FC 7 gis...
Page 68: ...Main menu 68 Instruction Manual DR FC 8 gis...
Page 72: ...Service program 72 Instruction Manual DR FC 9 is...
Page 88: ...Troubleshooting 88 Instruction Manual DR FC 10 gis...
Page 90: ...Maintenance frequency 90 Instruction Manual DR FC 11 gs...