15
PUMA 480LM
P48LMISE98
5.2 Connecting the air source
▪ Requirements
Pressure: 0.5 MPa or higher
Compressor requirements
※
1) The minimum pressure is 0.5 MPa.
The operational pressure should be more than 40% higher from the minimum
requirement.
If the discharge pressure of the compressor falls below the minimum requirement, this
may cause a failure of the air unit.
2) The recommended compressor is of the pressure-switch type.
3) Use only dehydrated clean air and, if the air contains moisture, make sure to install
an air dryer.
Note