OP000497
Troubleshooting
6-6
TRAVEL
Problem
Possible Cause
Remedy
Lack of power when
traveling.
Main relief valve pressure set too
low.
Adjust pressure.
Counterbalance valve bad.
Replace counterbalance valve.
Hydraulic motor performs poorly.
Replace hydraulic motor.
Damaged center joint seal.
Replace seal.
Hydraulic pump bad.
Replace hydraulic pump.
Oil leak from inside control valve.
Replace valve housing assembly.
Travel not smooth.
Tracks tension low.
Adjust tension.
Stone(s) jammed in track.
Remove.
Counterbalance valve bad.
Replace valve.
Hydraulic motor performs poorly.
Replace hydraulic motor.
Air in hydraulic motor.
Add oil.
Machine wanders, does
not travel straight.
Tracks have different tension.
Adjust so tracks have equal tension.
Hydraulic pump performs poorly.
Replace hydraulic pump.
Hydraulic motor performs poorly.
Replace hydraulic motor.
Oil leak from inside control valve.
Replace valve housing assembly.
Damaged center joint seal.
Replace seal.
Lever linkage loose.
Readjust linkage.