OP000756
Inspection, Maintenance and Adjustment
4-64
Replace Hydraulic Oil and Clean Oil
Suction Strainer
1.
Raise boom to its highest position. Tilt bucket back as far
as possible, and shut down engine.
NOTE:
See “Fluid Capacities” on page 4-16 for
capacity.
2.
Position a catch tank beneath hydraulic oil tank drain plug.
Open hydraulic oil tank breather cap. (See Figure 18 on
page 4-24). Remove drain plug from bottom of hydraulic oil
tank. (Figure 98). Allow all hydraulic oil to drain out.
NOTE:
See See “Fluid Capacities” on page 4-16 for
capacity.
CAUTION!
Be certain that hydraulic oil has cooled before draining
it. Hot oil could splash and cause burns.
Figure 97
Figure 98
Figure 99
Summary of Contents for DL160