120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
Copyright 2018 DoorKing
®
, Inc. All rights reserved.
Due to the nature of wireless communications, transmission and reception of data can never be guaranteed. Data may be delayed, corrupted (i.e., have errors) or be
totally lost. Although significant delays or losses of data are rare when wireless devices are used in a normal manner with a well-constructed network, DoorKing
wireless products should not be used in situations where failure to transmit or receive data could result in damage of any kind to the user or any other party,
including but not limited to personal injury, death, or loss of property. DoorKing, Inc. accepts no responsibility for damages of any kind resulting from delays or
errors in data transmitted or received using DoorKing wireless products, or for failure of DoorKing wireless products to transmit or receive such data.
Do not operate DoorKing wireless products in areas where cellular modems are not advised without proper device certifications. These areas include environments
where cellular radio can interfere such as explosive atmospheres, medical equipment, or any other equipment which may be susceptible to any form of radio
interference. DoorKing wireless products can transmit signals that could interfere with this equipment. Do not operate DoorKing wireless products in any aircraft,
whether the aircraft is on the ground or in flight. In aircraft, DoorKing wireless products
MUST BE POWERED OFF.
When
operating, DoorKing wireless products can transmit signals that could interfere with various onboard systems.
The driver or operator of any vehicle should not operate DoorKing wireless products while in control of a moving vehicle.
Doing so will detract from the driver or operator’s control and operation of that vehicle. In some states and provinces,
operating such communications devices while in control of a vehicle is an offence.
DoorKing Part Number
1470-080
Important Notice
Safety and Hazards
Program
Step
Factory
Default
Description
Options
Selection
Number
Function
Wireless RF Remote Module Tracker Expansion Board Programming ONLY
See the
900 MHz Wireless Baseboard manual
2333-065
and
Tracker Expansion Board manual
2358-065
for
ALL
tracker expansion board programming and wiring.
LED Display
Sets all parameters to Factory Default
Displays current signal strength between Baseboard and Tracker.
•
80 or lower -
GOOD
.
•
80-85 - Unreliable signal strength.
•
86-99 -
NO signal
.
Sets Wireless Tracker to act as Repeater
Do Not Change. Contact DoorKing tech support.
Repeater Mode OFF
Repeater Mode ON
Adding relay control delay to Trackers using the same Zone Addresses
If more than one tracker board is set to the same address (zone addresses), then
change this value to a unique number. Only program this for tracker boards with the
same addresses. Start out with a value of 1 then increase the next board to 2, then
the 3rd board to 3 etc... This will prioritize the relay access order of the same zone
address boards.
View the number of lost communication transactions with the base.
Use the arrows buttons to change the value.
Preset at Factory. Do Not Change. Contact DoorKing tech support.
This value is set to 2. No need to adjust.
Preset at Factory. Do Not Change. Contact DoorKing tech support.
Period Tracker board checks in with 1835 for schedule hold open (minutes).
Preset at Factory. Do Not Change. Contact DoorKing tech support.
Low Byte Value MAC address used only for 900MHz. Assigned during manufacturing.
When wireless communication is lost with the base for “X” number of minutes
defined in step 17, this step will instruct the tracker board what action to take.
Does nothing
Counts the number of lost communication transactions
Reboot the RF module only
Set RF module with net ID and channel selected
Initialize RF module then reboot RF remote module
Restore programming value, sets RF remote module net ID and CH, then reboots RF
module address boards.
E1 -
Relay connected to 4-pin terminal pins 1 & 2 is on for more than 5 seconds. Relay 1 in 1830 should be set for 00 seconds (0.25 second strike time)
E2 -
Relay connected to 4-pin terminal pins 3 & 4 is on for more than 5 seconds. Relay 2 in 1830 should be set for 00 seconds (0.25 second strike time)
A1 -
Board address is invalid for Tracker. Board address is improperly set as 0, 1, 2 or 19.
A2 -
Dual Mode - Bad Address, 18 or 19 not allowed.
Error codes on LED Displays for Baseboard and Tracker Board
View RF Signal Strength
Reset to Factory Defaults
Low Byte MAC
1835 Checkin Time (Factory Set)
Card Code Forwarding
(Factory Set)
0 or 1
0
1
5
5
2
0
1
2
3
4
5
0:
Off
5
Minutes
5
0
0
2
22
Same Zone Address
Relay Delay
Lost Wireless Communication
Options
(Factory Set)
View the Number of Lost
Wireless Communications
Air Busy Wait Time
(Factory Set)
23
24
25
26
21
17
18
19
Adjustable
View RF POT Setting
20
0 - 20
1 - 5
1 - 99
5
0 - 5
0 - 99
0 - 20
1:
counts the
number of
lost com
trans.
Sets maximum amount of allowable signal strength loss
1.
Press a button to activate LED display.
2.
Press
ENT
button and then use scroll buttons to display desired “
Program Step”
number from list below.
3.
Press
ENT
button to enter selected program step number.
4.
Select desired data while in program step using buttons.
5.
Press
ENT
button to
enter
selected data.
6.
Press
ENT
button
AGAIN
to
EXIT
programming
OR
after 10 seconds, board will
automatically EXIT
programming.
1470-065 Issued 11-18