TELEPHONE LINE WIRING
WIRE SIZE
MAX DISTANCE IN FEET
24 AWG
800
22 AWG
1600
20 AWG
2200
18 AWG
3600
1.5 Power
Wiring
Do not run telephone lines and high voltage lines in the same conduit. Separate high voltage and
telephone line conduits by at least six (6) inches.
POWER WIRING
WIRE SIZE
MAX DISTANCE IN FEET
18 AWG
100
16 AWG
200
The 1812 Plus system operates on 16.5 VAC. Do not power this device with 24 volt AC power.
Use the supplied power transformer, 16 VAC, 20 VA (or U.L. listed equivalent) to power the telephone
entry system. Do not power any other devices (electric strikes, magnetic locks, etc.) from this power
transformer. For wire runs up to 100 feet, use 18 AWG wire. For wire runs up to 200 feet, use 16
AWG wire.
1.6
Surge Suppression and Grounding
Proper grounding and the use of surge suppressers can significantly reduce the chance of
component failure because of static charges or surges. To be effective, ground connections should
be made with a minimum 12 AWG wire to a ground point within 10 feet of the device being protected.
The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a
grounding rod driven at least 10 feet into the soil.
A gooseneck mounting post anchored in
concrete does not make a good ground
.
It is highly recommended that telephone line surge suppresser (DoorKing p/n 1877-010) be installed
to help protect the system from phone line power surges.
It is highly recommended that a low voltage surge suppresser (DoorKing p/n 1878-010) be installed to
help protect the telephone entry system from power surges.
1812-161-E-1-10
Page
15