proGrammInG of remote controls

8.   proGrammInG of remote Controls

1.

   memory cleaning. To erase the codes from the memory press the “Tr” button and hold it down for 10 seconds. After that 

you will hear a click and two zeros will appear on the display, meaning that all the remote control codes are deleted.

2.   control’s code storing. To store the remote control code, press the “Tr” button and release it after two blinking zeros “00” 

appeared on the display. Than select a button on the remote control, which you will use to control the unit, and press 
it. The amount of the remote controls recorded in the receiver will appear on the display, for example “01”. release the 
button. Wait until a running zero “0” will appear on the display, meaning that a remote control has been recorded. 

3.   To add several remote controls, repeat the procedure of code storing for them. you can add 60 remote controls.
4.   If no control commands are given, the system will automatically exit from the waiting mode in 10 seconds. Should the 

control unit disconnect from the mains, the programmed data will be stored.

9.   release operatIon

1.  lift the cover.
2.  Insert the key and turn it by 180°
3.  Open or close the gate by hand.
4.  To link the operator, turn the key by 180° again.

WarnInG! 

Before releasing (linking) the operator, disconnect power supply.

 

Key

cover

180°

10.  maIntenanCe

 

The Swing-3000/5000 automatic system does not require any special servicing.

 

repairs may be carried out only by a qualified technician trained and certified at an authorized doorhan centre.

 

 Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency 
and has given instructions on proper operation and maintenance of the automated system.

 

When carrying out maintenance, it is recommended to use doorhan original spare parts.

 

carry out maintenance of the automatic system at least every six months.

 

regularly check if the door is properly balanced and moves smoothly when automatically operated.

 

 regularly check if the extreme positions of door travel are properly adjusted and safety devices are in good working 
condition.

 

 In case of power failure you may need to restore operator’s settings. Once the power supply is restored, check the 
automatic system for proper operation. If the operator settings have changed reprogram them following the instructions 
given in the corresponding paragraph of this manual (pay special warning to Operation time programming).

 

In case of power failure the door will stop. As soon as power supply is restored you can control the operator as usual.

 

After expiration of life time, the item shall be delivered in a specialized disposal point!

 

 If you have lost this manual, you may request for the duplicate copy to the following address: Kralovsky Vrch 2018, 
Kadan, 43201, czech republic, or by e mail: [email protected]

 

 The producer (doorhan) does not supervise the installation of operators, or carry out their maintenance, thus doorhan 
cannot be held liable for safety of installation, operation and maintenance of the equipment.

Summary of Contents for SWING-3000

Page 1: ...Safety instructions Operator unit Operator Installation Electrical Connections Extreme Positions Adjustment operator Programming programming of remote controls Release Operation maintenance Troubleshooting 2 2 3 5 5 8 10 11 12 12 12 13 Installation and Operating Manual ...

Page 2: ... remote control unit in a shockproof hermetic case 1 1 Range of use Leaf width m Leaf weight kg 2 00 1000 2 50 800 3 00 600 4 00 500 5 00 400 Leaf width m Leaf weight kg 2 00 800 2 50 600 3 00 400 Swing 3000 Swing 5000 CONTENTS 1 General Information 2 1 1 Range of use 2 1 2 Technical specifications 3 1 3 Operator package 3 2 Safety instructions 3 3 Operator unit 5 4 operator installation 5 4 1 Too...

Page 3: ...tions WARNING Important safety instructions It is important for the safety of persons to follow safety instructions Save these instructions Follow all instructions since incorrect installation can lead to severe injury Swing 3000 5000 was designed for automation of a street double leaf swinging gate with a load bearing structure Do not use the operator for other than intended purposes DoorHan shal...

Page 4: ...ystem DoorHan is not responsible for unstable work of the automatic system when using safety devices and accessories which are produced by other manufactures without agreement with DoorHan Never leave the electric motors in released condition This may cause uncontrolled movement of the gate leaves and consequently their breakdown Do not use the operator if it needs repair or adjustment as installa...

Page 5: ... M8 50 M8 10 5 6 2 Гайка М8 Nut M8 Stroke Stroke 793 300 993 500 Swing 3000 Swing 5000 88 126 88 126 1 Set of spanners 2 Set of slotted and cross screwdrivers 3 Set of drills for metal 4 Set of drills for concrete 5 Pliers 6 Hacksaw for metal 7 Electric drill 8 Tape measure folding rule 4 1 Tools 4 operator installation ...

Page 6: ...K OF INJURY Have a qualified technician lay the cables 220 240 V AC The cables must be laid in protective corrugated tubes Avoid contact of cables and moving parts of the door In case of supply cable damage use the suitable type of the cable Cables needed for installation of the Swing 3000 5000 operator and accessories if available cable 2 0 5 mm2 photocell transmitter stepped control button cable...

Page 7: ...tral hole and of the gate hinge shank The rear bracket has several holes which make installation of the operator easier and allow changing of the gate opening angle Depending on the position of the gate hinges you can lengthen or shorten the rear bracket Warning Increase of dimension B results in decrease of the gate opening angle and leaf angle speed and in increase of the operator s linear force...

Page 8: ...d fasten the front bracket to the gate leaf Наружняя сторона объекта Внутренняя сторона объекта Дополнительный кронштейн D B A External side of the object Internal side of the object Additional bracket 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 12 PE N L COM OP CL LAMP S B S PED OP CL COM STOP 24V S Lock COM OP CL FOTO 2 3 4 5 2 2 I COM F Tr COM NO NC 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17...

Page 9: ...device responses when the operator is activated than the gate leaves reverse or stop immediately and continue to move afterwards Response of the device does not effect operation of the closing gate If the gate is closed and the device has responded the gate will remain stationary WARNING If these terminals are not used install a jumper between contacts 13 15 14 15 CL FOTO contacts for connection o...

Page 10: ... Unscrew 2 tapping screws and remove the cover 2 Unscrew 2 tapping screws and remove the lead screw casing 6 3 Closed position 1 Put the gate leaf in fully closed position which can be determined by the mechanical stop 2 Unscrew fastening of the closing microswitch 3 Move the end microswitch along the guide until the microswitch contacts with the slide 4 Move the microswitch ahead until the micros...

Page 11: ... and release The leaves will begin to open After they reach the limit switches the leaves will stop At this moment give a control command Programming is done Press F again to leave the basic programming mode When the next control command is given the leaves will start moving in accordance with the programmed operation mode Display Function On default A Programming of pause time before automatic cl...

Page 12: ...be carried out only by a qualified technician trained and certified at an authorized DoorHan centre Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency and has given instructions on proper operation and maintenance of the automated system When carrying out maintenance it is recommended to use DoorHan original spare parts Carry...

Page 13: ...ent Remove the obstruction Bad wiring connection Check reliability of electric wiring connection Operator is released Engage the operator Operator stops suddenly Thermal protection is active Let the operator cool The gate does not open or close completely Wrong adjustment of limit switches Adjust the limit switches Wrong operator programming Reprogram the operator ...