31
Dalamatic Insertable Dust Collectors – Series DLM V
Installation, Operation and Maintenance Manual
SPECIFICATION
TABLE 3 – DALAMATIC INSERTABLE DUST COLLECTOR RANGE
*Designation codes:
A letter 'B', 'H', 'W', 'F', 'FAD' or 'S' is added after the figures to signify the type as follows:
B
=
basic type
H
=
as B, plus exit header
W
=
as H, plus weather cowl
F
=
as H, plus integral fan
FAD
=
as F, plus acoustic diffuser
S
=
high pressure
DLM V3/7
3.0 m
2
4
0.7 m
DLM V4/7
4.0 m
2
6
0.7 m
DLM V5/12
5.0 m
2
4
1.25 m
DLM V6/10
6.0 m
2
6
1.0 m
DLM V7/7
7.0 m
2
10
0.7 m
DLM V7.5/12
7.5 m
2
6
1.25 m
DLM V8/7
8.0 m
2
12
0.7 m
DLM V9/15
9.0 m
2
6
1.5 m
DLM V10/10
10.0 m
2
10
1.0 m
DLM V12/10
12.0 m
2
12
1.0 m
DLM V13/12
13.0 m
2
10
1.25 m
DLM V14/7
14.0 m
2
20
0.7 m
Collector
Filtration
Number
Bag
type*
area
of elements
length
DLM V15/12
15.0 m
2
12
1.25 m
DLM V15/15
15.0 m
2
10
1.5 m
DLM V18/15
18.0 m
2
12
1.5 m
DLM V20/10
20.0 m
2
20
1.0 m
DLM V21/7
21.0 m
2
30
0.7 m
DLM V25/12
25.0 m
2
20
1.25 m
DLM V30/10
30.0 m
2
30
1.0 m
DLM V30/15
30.0 m
2
20
1.5 m
DLM V38/12
38.0 m
2
30
1.25 m
DLM V45/15
45.0 m
2
30
1.5 m
DLM V50/12
50.0 m
2
40
1.25 m
DLM V60/15
60.0 m
2
40
1.5 m
Collector
Filtration
Number
Bag
type*
area
of elements
length
TABLE 4 – WEIGHTED SOUND PRESSURE LEVELS
All readings were taken in normal industrial areas, i.e. semi-reverberant surroundings, with local equipment silent.
Measurements were taken at maximum air flow conditions at 1.0 metre radius from the equipment housing
and 1.6 metres above base level, using a precision sound level meter and octave filter.
Noise levels of installed equipment may vary due to site conditions.
† Estimated data.
F1
K3
KV5
KV7
KV10
KV11
KV15
(0.75 kW) (1.5 kW)
(2.2 kW)
(3.0 kW)
(5.5 kW)
(7.5 kW) (11.0 kW)
With acoustic diffuser
76 dB(A)
73 dB(A)
74 dB(A)
76 dB(A) 79 dB(A)† 84 dB(A)
85 dB(A)
Without acoustic diffuser
91 dB(A)
89 dB(A)
92 dB(A)
93 dB(A)
94 dB(A)
97 dB(A)
99 dB(A)