15
Dalamatic Insertable Dust Collectors – Series DLM V
Installation, Operation and Maintenance Manual
INSTALLATION
north side of the building – fresh air drawn from the north side is usually cooler
and denser, and therefore has a lower moisture content. (South of the equator
the reverse will apply).
Layout and installation of air lines
The pipework between compressor and dust collector should be long enough
to act as a cooling device for the compressed air. A typical requirement for the
smaller installation would be 10 m (30ft) of 12 mm (½" NB) piping. For further
details see Table 6. The piping should be installed to provide a fall in the direction
of air flow to assist in the drainage of accumulated moisture. A moisture separator
should be provided at the lowest point of the installation.
Pressure relief
The manifold has a maximum operating pressure of 6.2 bar (see Table 5 in
‘Specifications’ section). It is a requirement that adequate precaution is taken
to avoid exceeding this pressure. Where a relief valve is supplied by Donaldson
this device has a relief rating of 25 dm³/s at 7.1 bar. Extra system relief will be
required if the connected supply can exceed this.
Controller
It is a requirement of the Supply of Machinery (Safety) Regulations 1992
to provide adequate isolation and emergency stop facilities. Due to the
varied nature of site installations this cannot be provided by Donaldson
but instead is the responsibility of the customer.
Always isolate power before opening the controller.
Each DLMV dust control collector is supplied with an EVC Controller, an IPC
Controller , an IPC (
∆Ρ
) Controller or a Delta P-C01 Controller to operate the
reverse jet cleaning system.
DLM V3/7 and V5/12:
2-way EVC, IPC , IPC (
∆Ρ
) Controller
,
Delta P-C01
Controller
or Control Box Assembly(Timer with box)
DLM V4/7, V6/10, V7.5/12, V8/7, V9/15, V12/10, V15/12
and V18/15:
3-way EVC, IPC or IPC (
∆Ρ
) Controller
,
Delta P-C01
Controller or Control Box Assembly(Timer with box)
DLM V7/7, V10/10, V13/12, V14/7, V15/15
and V20/10 (5-valve version):
5-way EVC, IPC or IPC (
∆Ρ
) Controller
, Delta P-C01
Controller or Control Box Assembly(Timer with box)
DLM V20/10 (10-valve version), V21/7, V25/12, V30/10, V30/15, V38/12,
V45/15, V50/12 and V60/15:
10-way IPC or IPC (
∆Ρ
) Controller
, Delta P-C01
Controller or Control Box Assembly(Timer with box)
For EVC Controller connections and set-up, refer to Publication 2698.
For IPC or IPC (
∆Ρ
) Controller connections and set-up, refer to Publication
2699.
For Delta P-C01 Controller connections and set-up, refer to IOM
AK0303001 and electrical drawings provided by Donaldson