Installation, Operation and Maintenance manual
6
PowerCore
®
Dust Collectors - Series CPV
None of the fan assemblies can be considered to be a fully sealed design,
indeed most are arranged with either an open inlet or an open outlet. For this
reason, the internal and external atmospheres can be considered the same
in terms of any potentially hazardous classification.
Standard fan assemblies should not exceed 3000 rpm (50 Hz supply) on
systems fitted with an inverter drive.
The filtration media is suitable for filtering particulate only (and not gas).
Some applications are prone to risk of fire. This risk can be reduced by pulse
cleaning.
•
Any extinguishing technique and material used must be suitable for the
flammable nature of the dust.
•
A water sprinkler system can be fitted as a special option.
Materials handled by the dust collector may be hazardous (e.g. toxic). Conduct
a Risk Assessment to ensure correct technique is employed.
The dust collector should be cleaned and put into a safe condition prior
to decommissioning. All equipment decommissioning/removal is to be
executed in a manner consistent with applicable codes, regulations and sound
engineering practice.