Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
32
speCIfICatIon
description and range
The DCE 2000 is an automatic reverse-jet cleaned, type of dust collector, designed
to handle large quantities of dust-laden air, and is capable of continuous operation
over extended periods. This reverse-jet cleaning system, which functions during
the normal course of operation, not only serves to maintain optimum filtering
efficiency at all times, but enables the collector to operate at a constant rating
– in that it maintains a uniform pressure drop across the collector.
The basis of the DCE 2000 is a module comprising a group of filter elements
mounted on a sealed frame. The elements are fitted side by side and the individual
table 5 – dCe 2000 serIes dust ColleCtor ranGe
-
10
°
to
+
60
°
C
(For applications outside this range refer to Donaldson)
-
500 mm W.G. or
-
1140 mm W.G.
(For positive pressures refer to Donaldson)
Collectors with fan:
as fan performance curves from shut-off to
ambient pressure (refer to Publication 2325)
3000 RPM (50 Hz) or 3600 RPM (60 Hz)
temperature range:
pressure range:
maximum fan impeller speed:
K3
K5
K7
K10 K11 SF40 SF55 SF75 SF110 SF150 SF185
(1.5 kW) (2.2 kW) (3.0 kW) (5.5 kW) (7.5 kW) (4.0 kW) (5.5 kW) (7.5 kW) (11.0 kW) (15.0 kW) (18.5 kW)
66 dB(A) 71dB(A) 72 dB(A) 74 dB(A) 75 dB(A)
74 dB(A) 73 dB(A) 75 dB(A)
78 dB(A) 77 dB(A) 78 dB(A)
** All readings were taken in normal industrial areas, i.e. semi-reverberant surroundings, with local equipment silent.
Measurements were taken at maximum air flow conditions at 1.0 metre radius from the equipment housing and 1.6 metres
above base level, using a precision sound level meter and octave filter. Noise levels of installed
equipment may vary due to site conditions.
Measured data.
Weighted sound pressure levels**:
(with acoustic diffuser fitted)
dCe f2012
12.0 m
2
12
1.0 m
dCe f2018
18.0 m
2
12
1.5 m
dCe f2024
24.0 m
2
16
1.5 m
dCe f2030
30.0 m
2
20
1.5 m
dCe f2036
36.0 m
2
24
1.5 m
dCe f2045
45.0 m
2
30
1.5 m
Filtration number element
unit type*
area
of elements
length
fabric element collectors
*designation codes
DCe 2000
=
Unit range
F
=
Fabric filter media
12, 18, 24 etc
=
Size (filtration area in m²)
r
=
Collector with rotary valve
H
=
Hopper type collector
V
=
Venting type collector
(unit supplied for external fan
fitment)
K5, K10 etc
=
Fan size, if fitted
e.g.
DCe F2030 K11
;
DCe F2018 H K5
Summary of Contents for DCE 2000 Series