Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
27
maIntenanCe
9 Fan maintenance – Open the access panel, remove HEPA filter if fitted and,
by looking through fan inlet eye, inspect fan thoroughly. If necessary, remove
all residual dust accumulation. (Although the fan is located on the clean side
of the collector, it is possible for low quantities of dust to migrate through the
filter media).
The fan should be inspected immediately after any period of
significant dust emission, i.e. due to damaged filter media or seal
etc.
The fan should be inspected immediately if there is any unexpected
noise, temperature or vibration.
The fan should be inspected every twelve months or immediately
following any misuse.
If inspection reveals any damage then the fan must not be put back
into service until properly repaired or replaced.
secondary or absolute filter replacement
(Refer also to Fig. 12)
1 Open fan section door.
2 Release tension latches and remove clamping frame(s).
3 Remove used element, place it directly into a plastic bag and then seal the
bag.
4 Place the new element in position, with the element seal against the
secondary/absolute filter seal frame.
5 Replace clamping frame(s) and secure tension latches.
6 Close fan section door.
7 If in doubt regarding the safe disposal of the used element, consult your
Environmental Health Officer.
fan assembly removal/replacement
The following procedure is based on removal from left-hand side of collector.
Isolate electric power supply.
1 Disconnect electrical cables from the terminal box.
2 Remove lifting brackets.
3 Remove top plate (to gain access to the top bolts for the outlet baffle, remove
outlet grille or back panel).
4 Remove the left-hand panel of the acoustic diffuser.
5 Remove internal baffles within the acoustic diffuser.