Ash Compressor Drawer
22
EN
Insert the motor shaft onto the worm screw shaft, ensuring
the flat sides of both shafts coincide (turn the worm screw
shaft
(16)
for this purpose if necessary), as shown in the
figure.
Fix the motor in place, bolting the sliding flange
(7)
on the motor in place with the bolts
(8)
and
washers
(9)
.
Fix the outer compressor drawer box in place using the
latches
(21)
.
Remove the boilers connections cap and
disconnect the indicated terminal strip.
Brown
Blue
Yellow
Green
Electrically connect the motor, connecting the hose
(2)
to
terminals
N
and
9
of the boiler terminal strip
(J2)
. (See
electrical diagram in boiler manual).
Place the door accessory
(23)
into the holes the
boilers side panels.