background image

D-DMEV

Continuous Decentralised Mechanical Ventilation Unit

Installation Instructions

1.0 SAFETY INFORMATION

• 

The device should not be used for applications other than those specified in this manual.

• 

After removing the product from its packaging, verify its condition. In case of doubt, contact 

a qualified technician. Do not leave packaging within the reach of small children or people with 
disabilities. 

• 

Do not touch the appliance with wet or damp hands/feet.

• 

This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been 
given supervision or instruction concerning use of the appliance in a safe way and understand 
the hazards involved. Children shall not play with the appliance. 

• 

Cleaning and user maintenance shall not be made by children without supervision.

• 

Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, 

gasoline, etc.

• 

If any abnormalities in operation are detected, disconnect the device from the mains supply 

and contact a qualified technician immediately. Use original spare parts only for repairs.

• 

The electrical system to which the device is connected must comply with regulations.

• 

Before connecting the product to the power supply or the power outlet, ensure that: 

 

- The data plate (voltage and frequency) corresponds to those of the electrical  

 mains. 
 

- The electrical power supply/socket is adequate for maximum device power. If  

 

not, contact a qualified technician.

• 

The device should not be used as an activator for water heaters, stoves, etc., nor should it 

discharge into hot air/fume vent ducts deriving from any type of combustion unit. It must expel 
air outside via its own special duct.

• 

Operating temperature: 0°C up to +50°C.

• 

The device is designed to extract clean air only i.e., without grease, soot, chemical or corrosive 

agents, or flammable or explosive mixtures.

• 

Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.). 

• 

Do not immerse the device or its parts in water or other liquids. 

• 

Turn off the main switch whenever a malfunction is detected or when cleaning.

671982  

|  

SepTemBer 2021

pAGe 1

Summary of Contents for D-DMEV

Page 1: ...etc If any abnormalities in operation are detected disconnect the device from the mains supply and contact a qualified technician immediately Use original spare parts only for repairs The electrical system to which the device is connected must comply with regulations Before connecting the product to the power supply or the power outlet ensure that The data plate voltage and frequency corresponds t...

Page 2: ...he appropriate window kit which is not included Attention do not mount the product on the window without this kit 1 1 Hazard Symbols REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing operating or maintaining this product 1 2 Important Information This manual contains important information on the safe and appropriate assembly transport commiss...

Page 3: ...cy aerodynamic fan with winglet blades to optimise quietness and efficiency Single phase EC Brushless motor with integral thermal protection Motor mounted on high quality ball bearings The fan is double insulated no earth connection is required Trickle speed selectable during installation Option to boost from trickle or from off through LS connection Installation type selection available through w...

Page 4: ...iew Model D DMEV100 D DMEV150 A 164 218 B 70 97 C 46 52 D 116 149 ØE 99 148 Weight 0 6 1 2 Dimensions 7 3 2 Installation Preparation 8 9 10 11 D DMEV100 ø99mm D DMEV150 ø149mm Ø 12 13 3 3 Surface Cable Installation 4xø5mm 8A 14 9A 15 671982 September 2021 PAGE 4 ...

Page 5: ...1 5 mm2 3 x 0 5 1 5 mm2 HT 3 x 0 5 1 5 mm2 4 x 0 5 1 5 mm2 3 6 Wiring Diagram Wiring 24 3 7 Installation Type Setting Installation type can be selected using JUMPER 1 between the following options through wall or ducted Section 3 9 3 8 Trickle Speed Setting Trickle speed can be selected using JUMPER Section 3 9 671982 September 2021 PAGE 5 ...

Page 6: ...light switch Figure 24 Trickle speed can be set to off Section 3 9 To deactivate the humidistat function turn the trimmer HY completely clockwise Automatic humidistat operation when the percentage of Relative Humidity exceeds the settable threshold fan speed automatically increases to comfort boost speed intermediate between the selected trickle speed and the boost speed When the percentage of Rel...

Page 7: ...components can be segregated into mixed plastic and widely recycled Cardboard packaging wood and other paper components can be largely recycled or fully processed in energy from waste centres Filter Disposal Cardboard framed filters should be fully processed in energy from waste centres contact your local civic amenity site household waste recycling centre regarding metal wire framed filters Remai...

Page 8: ...sions of equipment and the right is reserved to make such changes without prior notice 671982 September 2021 PAGE 8 Domus Ventilation Block C Van Court Caerphilly CF83 3ED United Kingdom Email vent info domusventilation co uk Tel 03443 715 523 www domusventilation co uk Technical or commercial considerations may from time to time make it necessary to alter the design performance and dimensions of ...