Ventilation of installation area
Make sure that the room where the appl,ance is installed has permannet ventilation
penings on an outsidewall or ventilation ducts, in order to ensure adequate air flow as
proscribed by current legislation.alloponings must:
1.Have a minimum working section of 100 cm2;
2.be made in such a way as prevents them being blocked in manner, from inside or outside;
3.be provided witf suitable protection to ensure the size of the ventilation opening is not
reduced;
4.be positioned at such a height from floor level as not to interfere with the disharge of
combustion fumes. If openings are made the wall of an adjacent room, the must have
direct ventilation and must not be:
1.a bedroom;
2.a common area of the builtding in question;
3.a fire hazart area.
Before testing and inspecting the appliance check that the adjacent room, which shares the
wall in which theventilation opening has been made, does not low pressure due to another
user, moreover, ensureadequate air flow between the rooms is quaranteed by permanent,
unobstructed openings, foreaxample by increasing the gap between the bottom of the door
and the floor. Discharge of combustion products must be quaranteed by means of a hood
which, in turn, must be connected to a chimney, a flue, ordirectly to outside.
Electrical connection
your DOMINOX hob come