![Dominox DHG 301 1G BK F C Manual Download Page 19](http://html1.mh-extra.com/html/dominox/dhg-301-1g-bk-f-c/dhg-301-1g-bk-f-c_manual_2519779019.webp)
Technical Information on Gas Burners
A Burner
1kW
SR Burner
1.75kW
R Burner
3kW
Wok Burner
(2.5 kW)
Ø 100
Wok Burner
(3.3 kW)
Ø 100
Wok Burner
(3.8 kW)
Ø 126
G30-30
mbar LPG
(0.50 mm)
G30-30
mbar LPG
(0.82 mm)
G30-30
mbar LPG
(0.89 mm)
G30-30
mbar LPG
(0.85 mm)
G30-30
mbar LPG
(0.65 mm)
G30-30
mbar LPG
(0.98 mm)
G20-20
mbar
NATURAL
GAS
(0.72 mm)
G20-20
mbar
NATURAL
GAS
(1.35 mm)
G20-20
mbar
NATURAL
GAS
(1.15 mm)
G20-20
mbar
NATURAL
GAS
(1.28 mm)
G20-20
mbar
NATURAL
GAS
(1.15 mm)
G20-20
mbar
NATURAL
GAS
(0.97 mm)
The use of large pans than those given could lead to overheating of the
knobs anf top.
Franke is not liabla for any damage deriving from such incorrect use.
Overall rated heat capacity: see dataplate on underside of hob.
Power supply voltage: 220/240 V AC 50-60 Hz.
The appliance is compliant with the following EU Directives:
90/396/EEC (gas):
73/23/EEC of 19/02/73 (Low Voltage);
89/336/EEC of 03/05/89 (Electromagnetic Compatibility);
93/68/EEC of 22/07/93 and subseguent modifications.
1.Nitril/Klingerit Gasket
2.Elbow
3.LPG Hose Entrance
Complete the installation by using gasket in the
middle for the LPG hose entrance indicated on
the above figure during the natural gas LPG
conversion.
14
Technical data
Appliance cat. II2H3B/P