background image

 

Owner Installation Instructions 

Dominator

®

23

Final Set Up

34

fi g

Step 24 - Setting of Courtesy Light Time

The  courtesy  light  time  can  only  be adjusted with the 

Universal Programmer (PG-3). 

Step 25 - Setting the Pet Mode position

The default Pet Mode height can be changed as follows:

Make sure the door is closed, then press and hold 

the PLUS (+) button for six (6)  seconds  

(Fig.34)

until  you  hear  three  beeps  and  the  OPEN  and 

CLOSE LEDs fl ash rapidly.

Press the PLUS (+) or MINUS (-) button

 

to move 

the door to the desired pet mode open position.

Press the SET button to record the new position.

When activated, Pet Mode drives the door to the preset 

position from either above or below.  Pet Mode’s active  

status is indicated by both the OPEN and CLOSE LIMIT 

LEDs being illuminated.  If a Pet Mode button is pressed 

while  the  door  is  moving  the  door  will  stop.    If  a  Pet 

Mode  button  is  pressed  when  the  door  is  in  the  Pet 

position, then the door will close.

Step  26  -  Installing  the  Wall  Mounted 

Transmitter (Optional)

Remove the faceplate from the transmitter.

Affi x the baseplate in a convenient wall location 

that  is  out  of  reach  of  children  and  convenient 

to the customer 

(Fig.35).

 Make sure the door is 

visible from this location.

Replace the faceplate.

To  code  the  transmitter,  see  Step  19  on  page 

20.

Step 27 - Re-initialising the Opener

Press and hold the SET Button for two (2) seconds, 

the beeper will sound once 

(Fig.36).

  

The door will start to move and re-calculate force 

margins. The door can move between the open and 

close limit positions up to four (4) times (depending 

on  the  position  of  the  door  and  the  power  up 

condition). 

A single beep will be heard once the initialisation is 

complete. The door is now ready for use.

a.

b.

c.

a.

b.

c.

d.

a.

b.

c.

35

fi g

36

fi g

Summary of Contents for GDO-7v2

Page 1: ...GDO 7v2 INSTALLATION INSTRUCTIONS OWNERS COPY Overhead Garage Door Opener ...

Page 2: ...t that such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Dominator Australia Pty Ltd Garage Door Opener Dominator Australia Pty Ltd hereby further expressly excludes all or any liability for any injury damage cost expense or claim whatsoever suffered by any person a...

Page 3: ...Force 18 Safety Obstruction Force Test 18 Adjustin Safety Obstruction Forces 19 Coding Transmitters 20 Door 20 Courtesy Light 20 Vacation Mode 20 Pet Pedestrian Mode 20 Remotely Coding Transmitters 21 Deleting Transmitter Codes 21 Accessories 22 Photo Electric Beam 22 Auto Close 22 Final Set Up 23 Courtesy Light Time 23 Pet Mode Door Height 23 Wall Mounted Transmitter 23 Re Initialising 23 Paramet...

Page 4: ...llow this warning DO NOT allow children to operate the GDO 7v2 Serious personal injury and or property damage can result from failure to follow this warning Regularly check to make sure that the safety obstruction force is working correctly and is tested and set as per page 18 of this manual Failure to follow these instructions could result in serious personal injury and or property damage This te...

Page 5: ...nect the power cord from mains power before making any repairs or removing covers Only experienced service personnel should remove covers from the opener When using auto close mode a photo electric beam must be fitted correctly and tested for operation at regular intervals Extreme caution is recommended when using auto close mode All safety rules must be followed In order for the GDO 7v2 to sense ...

Page 6: ...oswitches During installation the handheld transmitter can be programmed to set the limits positions Anti travel electronic brakes The GDO 7v2 features an anti travel electronic brake mechanism to ensure the opener stops the door at exact location ISS intelligent safety obstruction system While the door is performing a close cycle should it hit an obstacle or be restricted in some manner it will a...

Page 7: ... may also wish to open the door to a height suitable only for pedestrian access The door opening position is also programmable Auto close mode The opener can be programmed to automatically close after an open cycle The auto close time is adjustable It is compulsory to install a P E Beam if this mode is selected otherwise the door may cause personal injury or damage to property Photo Electric P E B...

Page 8: ...emains steady on when the open limit position has been reached FORCE MARGIN SET Button The obstruction force margin is set automatically during installation The margin can be adjusted manually using the Force Margin Set button White Holding the Force Margin Set button and pressing Plus or Minus buttons will increase or decrease the amount of force The Force Margin Set should only be used if enviro...

Page 9: ...Owner Installation Instructions Dominator 9 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 01 fig J4 0800 366462 ...

Page 10: ...kage Contents GDO 7V2 drive unit 1 Keyring transmitters 2 Wall mounted transmitters not available all models 1 Shuttle assembly 1 Door attachment arms 2 Hardware pack 1 Installation Manual 1 Packaged Seperately C Rail Kit packed seperately 1 02 fig ...

Page 11: ...lation can lead to severe injury Follow ALL installation instructions 03 fig Step 1 Connect the Powerhead to the C Rail Locate and insert the powerhead s shaft into the C Rail s sprocket as shown in Fig 03 Step 2 Secure the C Rail Fix the two track brackets as shown in Fig 04 Fix with the four screws supplied in accessory pack 04 fig ...

Page 12: ...or a sectional panel door on tracks Fig 05 proceed with the installation from Step 5 For a one piece door on tracks Fig 06 proceed with the installation from Step 5 For a one piece door without tracks on springs Fig 07 proceed with the installation from Step 9 05 fig 06 fig 07 fig Door Sectional door with track Door Track One piece door with track One piece door without track ...

Page 13: ... Step 6 Attach the Rail to the Wall Bracket Attach the C Rail assembly to the wall bracket with the 90mm long clevis pin and secure with the supplied snap pin Fig 10 Leavethepowerheadinitspackingboxforprotection during installation Step 7 Secure the Powerhead to the Ceiling Raise the powerhead from the packing box and support it in the horizontal position with a step ladder Open the garage door Re...

Page 14: ...ll be the height at which to mount the wall bracket Centre the bracket along the line detemined in Step 9 Using the bracket as a template mark a minimum of two holes and drill with appropriate size bit For a more secure fitting the wall bracket can be anchored using more than two holes Secure the bracket to the wall using IF CONCRETE OR BRICK 8mm or 5 16 loxins or dynabolts IF TIMBER wood screw 20...

Page 15: ...s FOR SECTIONAL AND ONE PIECE DOORS WITH TRACK Assemble the bent and straight arms with bolts and nuts supplied in the accessory pack Fig 17 Always use both bent and straight arms Connect the assembled arm to the bracket and the disengaged trolley with clevis and snap pins The angle A must be more less than 10 Fig 18 WARNING Connecting the bent arm other way around may damage the door The straight...

Page 16: ... then turn back one notch to illuminate again Step 15 3 Set the Limits Positions Press and hold the MINUS button until the door reaches the desired close limit position Single presses will the inch the door closed Fig 21 Press the LIMIT SET button to store the close position into memory Fig 21 Press and hold the PLUS button until the door reaches the desired open limit position Single presses will...

Page 17: ...with the close limit position press Button 2 to store this in memory Press Button 1 to open the door When approx 2cm from the desired open position press and hold Button 3 for two seconds then release Each press of Button 1 will allow you to inch the door open Keep doing this until the door reaches the desired open limit position If the door is opened too far press Button 4 to inch the door toward...

Page 18: ...ly under the door Fig 25 Press the OPERATE button to close door The door should strike the object and start to re open Step 17 2 Testing Open Cycle Press the OPERATE button to close the door Fig 24 Press again to open the door When the door reaches the half open point grab the bottom rail of the door firmly and the door should stop If the door does not reverse readily when closing or stop when open...

Page 19: ...PLUS button is pressed to indicate a force increase If the OPEN LIMIT LED flashes continuously when pressing the PLUS button this indicates that the maximum setting has been reached Test the force again as per Steps 17 1 and 17 2 Step 18 2 To Decrease Force Pressure Hold down FORCE MARGIN SET button Fig 26 While holding the FORCE MARGIN SET button press the MINUS button Each press decreases the fo...

Page 20: ...c d 27 fig 28 fig 29 fig Briefly press the DOOR CODE button three times then press it again and hold will beep four times on fourth press Fig 29 Press one of the four buttons on the transmitter for two 2 seconds pause for two 2 seconds then press the same button again for two 2 seconds Release the DOOR CODE button Press the transmitter button to test To change the default pet pedestrian door openi...

Page 21: ...ld again for two seconds and then release Wait for 10 seconds and then press the new transmitter s button to test Step 21 Deleting Programmed Codes Step 21 1 Deleting a Stored Transmitter Code Select the transmitter you want to delete Press and hold the DOOR CODE BUTTON Fig 31 Press the transmitter button you would like to delete for two seconds pause for two seconds press again for two seconds an...

Page 22: ...tarts after the P E Beam s path is broken the Auto close timer has been set If the P E path is not broken the door will remain open until the path is broken If the opener incurs a physical obstruction i e not from the P E Beams while closing the door will re open and not Auto close until the P E Beam s path is broken again Step 22 1 Setting Auto close Time Hold down the AUTO CLOSE TIME button Fig ...

Page 23: ...f a Pet Mode button is pressed while the door is moving the door will stop If a Pet Mode button is pressed when the door is in the Pet position then the door will close Step 26 Installing the Wall Mounted Transmitter Optional Remove the faceplate from the transmitter Affix the baseplate in a convenient wall location that is out of reach of children and convenient to the customer Fig 35 Make sure t...

Page 24: ...e p O g n i h s a l F g n i s o l C Door travel stopped Flashing Door obstructed when opening Flashing s e v o m r o o d s a s p e e B g n i h s a l F g n i s o l c n e h w d e t c u r t s b o r o o D Opener overloaded Alternating flashes Alternating flashes Door in open position with Auto Close mode selected One second flashes Mains power interrupted Rapid flashes Flashing ...

Page 25: ... E P O n e h t E M I T E S O L C O T U A e m i t y a l e d e s o l c o t u a e h t s e s a e r c e D E S O L C n e h t E M I T E S O L C O T U A e m i t y a l e d e s o l c o t u a t l u a f e d y r o t c a f e h t s t e s e R T E S n e h t E M I T E S O L C O T U A FORCE MARGIN SET AUTO CLOSE TIME then SET Reloads the factory default light time n e h t s t i m i L s n o i t i s o p t e s s t i m ...

Page 26: ...M F H U e p y t r e v i e c e R 14 x 4 button Transmitter Codes y t i c a p a c e g a r o t s e d o c r e v i e c e R r e t t i m s n a r T M F y c n e u q e r f i t l u M F H U y c n e u q e r f r e t t i m s n a r T g n i p p o h e d o C e p y t g n i d o C s e d o c m o d n a r n o i l l i b 9 2 4 r e v O s n o i t a n i b m o c e d o c f o r e b m u N m h t i r o g l a n o i t p y r c n e r a ...

Page 27: ...ly Door limits positions need to be reset Reset limits positions Step 16 4 page 17 Door will not open fully Door limits positions need to be reset Reset limits positions Step 16 4 page 17 Courtesy light not working Globe down Replace globe Edison type 240V 60W Globe keeps blowing Incorrect globe voltage must be 240V AC Replace globe Edison type 240V 60W Auto close not working PE Beam or wiring fau...

Page 28: ...he door does not operate smoothly call your installer Yearly Dominator suggests you contact your installer to perform an annual door service CAUTION Frequently examine door particularly cables springs and mountings for signs of wear damage or imbalance Do not use if repair or adjustment is needed since a fault in the installation or an incorrectly balanced door may cause injury AS3350 Adjustments ...

Page 29: ...Owner Installation Instructions Dominator 29 Spare Parts ...

Page 30: ...ch is not in accordance with the instructions set out in installation instruction manual l attempted or complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by BND to carry out such modification or repairs m faulty or unsuitable wiring of structure to which the product is fixed or connected n radio including citizen band transmission or...

Page 31: ...Owner Installation Instructions Dominator 31 ...

Page 32: ... reserved No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to change specification without notice E OE B D Doors NZ Limited PO Box 24 131 67 Wickham Street Linwood Christchurch New Zealand Tel 64 0 3 384 5145 Fax 64 0 3 384 5148 ...

Reviews: