EN
TL, FO
Installing and connecting the refrigeration container
21
24 V (with additional module DT-32)
A
1. Before starting up the device for the first time, check whether the operating volt-
age and the battery voltage match (see type plate).
2. Make sure that the cable at the positive battery terminal (fig.
tected with a 25 A fuse (fig.
3. Plug the DC connection cable into the DC socket of the refrigeration container
4. Connect the red cable (fig.
rd, page 7) to the positive battery terminal
5. Connect the black cable (fig.
bk, page 7) to the negative battery terminal
Notes on the battery monitor
The product is equipped with a battery monitor that protects your vehicle battery
against excessive discharging when the device is connected to the on-board supply.
If the refrigeration container is operated when the vehicle ignition is switched off, it
switches off automatically as soon as the supply voltage falls below a settable level.
The refrigeration container will switch back on once the battery has been recharged
to the switch-on voltage level.
!
A
> 6 m
6.5 m – 10.5 m
11 m – 15 m
Ø 6 mm²
Ø 10 mm²
Ø 16 mm²
NOTICE! Risk of damage to the device!
Make sure that the polarity is correct.
CAUTION! Health hazard!
If the refrigeration container switches itself off, the food contained inside
it will not be cooled.
NOTICE! Risk of damage!
When the refrigeration container is switched off by the battery monitor,
the battery will no longer be fully charged. Avoid starting repeatedly or
operating power consumers without longer charging phases. Make
sure that the battery recharges.
TL200-450-600-FO200-450-600-800-1000_OPM_4445102370_EMEA16_202x-xx-xx.book Seite 21 Sonntag, 21. März 2021 1:13 13