EN
Installing and connecting the refrigeration container
TL, FO
20
!
1. Observe the minimum clearances for the place of installation (fig.
2. Place the refrigeration container on a stable and even floor.
7.1
Operation with AC power
1. Plug the AC connection cable into the AC power supply connection (fig.
2. Connect the refrigeration container to the AC power supply.
7.2
Operation with DC power
A
For safety reasons, the refrigeration container is equipped with an electronic system
to prevent the polarity being reversed. This protects it against reversed polarity when
connecting to a battery and against short circuiting.
A
➤
Determine the required cross section of the cable in relation to the cable length
as follows:
12 V
WARNING! Fire hazard!
•
When positioning the device, ensure the supply cord is not trapped
or damaged.
•
Do not locate multiple portable socket-outlets or portable power
supplies at the rear of the device.
NOTICE! Risk of damage to the device!
Disconnect the refrigeration container and other electric consumers
from the battery before you connect the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
NOTICE! Risk of damage to the device!
To avoid voltage drops and loss of performance, keep the cable as short
as possible and avoid joins.
Therefore avoid additional switches, plugs or power strips.
> 3 m
3.5 m – 5 m
5.5 m – 8.5 m
9 m – 13 m
13.5 m – 15 m
Ø 6 mm²
Ø 10 mm²
Ø 16 mm²
Ø 25 mm²
Ø 35 mm²
TL200-450-600-FO200-450-600-800-1000_OPM_4445102370_EMEA16_202x-xx-xx.book Seite 20 Sonntag, 21. März 2021 1:13 13