EN
SMP439, 439-08
Installing the device
15
•
Lay the cables in accordance with VDE 100 (Germany).
•
Use the following cable colors:
–
Red: positive connection
–
Black: negative connection
•
Do not reverse the polarity. Reversing the polarity of the connections will cause a
great spark and the internal fuses will melt.
1. Connect the positive cable from the battery charger to the positive terminal of
the battery.
2. Connect the negative cable from the battery charger to the chassis of a vehicle.
Keep the negative cable away from battery and fuel line.
3. Connect the battery charger to supply mains.
Disconnecting the battery
1. Disconnect the battery charger from supply mains.
2. Disconnect the negative cable from the chassis of the vehicle.
3. Disconnect the positive cable from the positive terminal of the battery.
Using with a LIN bus and battery sensor
You can find a sample wiring diagram for using the device with a LIN bus and battery
sensor in fig.
The LIN bus plug pins are assigned as follows:
No. in
Explanation/function
1
Consumer
2
LIN/CI bus control system
3
Battery sensor
4
Battery
5
Fuse
Pin in
Allocation
1
BATT +12V
2
LIN bus data I/O
3
BATT GND
Summary of Contents for SMP439
Page 3: ...SMP439 439 08 3 SMP 439 1 2 3 4 6 5 8 7 1...
Page 4: ...SMP439 439 08 4 SMP 439 08 1 2 4 3 5 6 8 7 2...
Page 210: ...RU SMP439 439 08 210 A I 2 2 1 D 8...
Page 211: ...RU SMP439 439 08 211 A 2 2 D...
Page 212: ...RU SMP439 439 08 212 25 A...
Page 213: ...RU SMP439 439 08 213 2 3 D A...
Page 214: ...RU SMP439 439 08 214 2 4 A...
Page 215: ...RU SMP439 439 08 215 3 4 PerfectCharge SMP439 SMP439 08 12 6 50 250 BMU AGM NiCd NiMH...
Page 218: ...RU SMP439 439 08 218 40 C A M4 5 1 2 6 2...
Page 219: ...RU SMP439 439 08 219 25 VDE 100 1 2 3 1 2 3 LIN LIN 3 5...
Page 221: ...RU SMP439 439 08 221 I 7 1 IU0U 1 5 3 2 6 4 1 2 3 4 5 225...
Page 224: ...RU SMP439 439 08 224 8 A 1 2 3 4 5 6 7 AGM 14 4 14 7 13 8 13 8 13 6 13 8 1 1 2 1 3 1...
Page 225: ...RU SMP439 439 08 225 9 I 10 dometic com dealer 1 5 3 2 6 4...