EN
SMP301-07
Installing the power supply unit
13
6.2
Connecting the power supply unit
Please note that flat plugs P1 – P6 are individually fused via plug-in fuses F1 – F6 in the
following manner:
➤
Press the two tabs (fig.
3
1, page 4) in the direction indicated by the arrows and
lift the cover off (fig.
3
2, page 4).
➤
Connect the positive terminal of the consumer units to the flat plugs P1 – P5
(fig.
1
11 – 15, page 2).
➤
Connect the negative terminal of the consumer units to one of the flat plugs P7
(any pin) (fig.
1
17, page 2).
➤
Connect the positive terminal of the battery to one of the flat plugs P6 (fig.
1
4,
page 2).
➤
Connect the negative terminal of the battery to one of the flat plugs P7 (any pin)
(fig.
1
17, page 2).
➤
Connect the AC connection cable to the AC plug (fig.
1
1, page 2).
➤
Ensure that the cable length between the battery and the power supply unit is not
more than 2 m.
➤
Secure all cables with strain relief clamps.
Flat plug
Fuse
Fuse assignment
Maximum permissible
current
P1
F1
10 A
15 A
P2
F2
10 A
15 A
P3
F3
5 A
15 A
P4
F4
5 A
15 A
P5
F5
10 A
15 A
P6
F6
20 A
20 A
SMP301-07-IO-7s.book Seite 13 Montag, 16. Januar 2017 1:08 13