
19
Dimensions
Weight
Capacity (water temp. 15 °C)
Water efficiency
Electrical supply
Total power consumption
Operation period
Sound level when installed in under-sink cupboard
Environmental specifications
air temperature
relative humidity
Requirements regarding feed water to the water
purifier:
Chemical requirements:
conductivity
/salt
/chloride
cloudiness
turbidity
pH
calcium: Ca2+
magnesium: Mg2+
/hardness
iron: Fe2+
iron: Fe3+
manganese: Mn
COD-Mn: O2
* higher values require an extra prefilter
Microbiological requirements
Heterotrophic bacteria (48 hour test count)
Coliform bacteria
E.coli
Water flow
Domestic water supply pressure
Water temperature
height 466 mm
depth 460 mm (395 mm without hand-grip and hoses)
width 225 mm
29 kg when supplied
33 kg when filled with water
3.1 (±0.4) litres/minute
approx. 80 % at constant flow
approx. 50 - 75 % including flushing
230 V, 50 Hz, 10 A, earthed socket
530 W
20 minutes
< 60 dB(A)
2 - 43 °C
25 – 95 %
<200 mS/m
<1500 mg/l
<900 mg/l
slight/ distinct*
< 1 FNU
4 - 10
<140 mg/l
<20 °d
<5 mg/l*
<0.3 mg/l *
<0.8 mg/l*
<10 mg/l
1000/ml
1000/100 ml
100/100 ml
>10 l/min
150 - 1000 kPa (1.5 - 10 bar)
2 - 40 °C
TECHNICAL DATA
}
Summary of Contents for RO400
Page 3: ...3 PRODUCT DESCRIPTION 13 12 11 14 6 7 3 3 1 5 8 9 4 2 10...
Page 11: ...11 MAINTENANCE...
Page 26: ...26...
Page 33: ...33 WARTUNG...
Page 48: ...48...
Page 55: ...55 MAINTENANCE...
Page 70: ...70...
Page 77: ...77 MANTENIMIENTO...
Page 92: ...92...
Page 99: ...99 MANUTENZIONE...
Page 114: ...114...
Page 121: ...121 UNDERH LL...
Page 136: ......