EN
Connecting the refrigerator-oven combination
RMLT9xxx
30
AC power
➤
Connect the refrigerator with the mains plug to an AC socket.
DC power
I
Please note the following cable sizes:
–
< 6 m (interior): 6 mm
2
–
> 6 m (interior): 10 mm
2
–
Connections D+ and S+: 1 mm
2
–
Cable fed via drawbar (caravans only): 2.5 mm
2
➤
Connect the DC heating cartridge with the shortest possible cable.
➤
Run the cable to the DC heating cartridge via a relay controlled by an ignition
socket to prevent the battery from completely discharging if the engine is
switched off accidentally (fig.
u
, page 13).
➤
RMLT9330/9430 only
:
Connect a 12 V continuous supply to the connection
for lighting.
➤
RMLT9331/9335/9431/9435 only
:
Connect a 12 V continuous supply to
the connection for electronic control unit.
D+ (RMLT9335/9435 only)
In automatic mode, the refrigerator selects the most favourable mode available. The
refrigerator is only operated with direct current when the vehicle engine is running.
The electronics of the refrigerator uses the signal D+ from the light system to detect
the running engine.
➤
Connect the D+ connection to the controls (fig.
t
D, page 12) with the
respective terminal of the vehicle.
NOTE
•
The supply line to the DC heating cartridge must be protected by
20 A.
•
RMLT9330/9430
:
The supply line to the lighting must be
protected by 2 A.
•
RMLT9331/9335/9431/9435
:
The supply line to the electronic
control unit must be protected by 2 A.
RMLT9xxx-I-West.book Seite 30 Donnerstag, 7. Dezember 2017 12:22 12
Summary of Contents for RMLT 933 Series
Page 2: ......
Page 5: ...RMLT9xxx 5 1050 250 1050 250 5 15 25 mm 25 mm 25 mm 6...
Page 6: ...RMLT9xxx 6 8 1 7 2 3 1 5 3 4 1 2 170 mm 1300 mm 65 55 1 0 3 5 9 1 0...
Page 7: ...RMLT9xxx 7 1 2 3 4 1 3 2 4 LS230 LS330 a LS230 LS330 b LS230 LS330 c LS230 LS330 1 2 3 d...
Page 8: ...RMLT9xxx 8 1 2 3 4 e 1 2 f 1 2 3 RMLT9430 g 1 2 3 RMLT9431 RMLT9435 h i 1 2 j...
Page 9: ...RMLT9xxx 9 2x l 2x k n m o...
Page 13: ...RMLT9xxx 13 RMLT93 RMLT94 u...