If the ventilation grille of the air inlet vent cannot be installed flush with the floor of the
niche, you need to install an inlet vent in the floor:
➤
Make an air inlet vent in the floor (fig.
3
6, page 4) behind the refrigerator-oven
combination near the gas burner.
➤
Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig.
8
, page 6).
6.4
Oven ventilation using a roof flue
A
Proceed as follows (fig.
9
, page 6):
➤
Make a round hole with a diameter of 60 mm in the roof.
➤
Secure the roof flue (
1
)
in the hole.
➤
Slide the flexible flue pipe (
2
)
up into the roof flue.
➤
Insert the bottom end of the flue pipe (
4
)
onto the end of the flue outlet (
5
).
➤
Attach the flue pipe using the screws which were supplied with the roof flue (
3
).
Alternatively, you can use a worm gear hose clamp.
➤
Fit a detachable panel (fig.
3
5, page 4) above the oven.
NOTICE!
•
Use a Truma AK 3 roof flue and Truma flue pipes. These have been
tested and approved for use.
•
Materials must not be located near the roof flue and flue pipe which
are unsuitable for temperatures of above 120 °C.
•
Lay the flue duct so that it rises gradually. The installation height of the
flue pipe between the top of the oven and the air outlet on the roof
flue must be at least 200 mm. A maximum of 1500 mm is possible.
•
Keep the surrounding walls and components at a distance of at least
50 mm.
RMLT9xxx-I-West.book Seite 21 Donnerstag, 7. Dezember 2017 12:22 12
Summary of Contents for RMLT 933 Series
Page 2: ......
Page 5: ...RMLT9xxx 5 1050 250 1050 250 5 15 25 mm 25 mm 25 mm 6...
Page 6: ...RMLT9xxx 6 8 1 7 2 3 1 5 3 4 1 2 170 mm 1300 mm 65 55 1 0 3 5 9 1 0...
Page 7: ...RMLT9xxx 7 1 2 3 4 1 3 2 4 LS230 LS330 a LS230 LS330 b LS230 LS330 c LS230 LS330 1 2 3 d...
Page 8: ...RMLT9xxx 8 1 2 3 4 e 1 2 f 1 2 3 RMLT9430 g 1 2 3 RMLT9431 RMLT9435 h i 1 2 j...
Page 9: ...RMLT9xxx 9 2x l 2x k n m o...
Page 13: ...RMLT9xxx 13 RMLT93 RMLT94 u...