5
CLEARANCES
Minimum clearances in inches to combustible
materials are:
G :
Top 0
K: Side 0
L: Bottom 0
M: Rear 1
Clearance M between the rear-most part of the
refrigerator and the wall behind the refrige-
rator.
Clearance N on top of the condenser is related
to the minimum ventilation height.
See Fig. 5 and examples below.
Fig.5
MEASUREMENTS
Distance
Refrigerator Overall Installation
Recess
between top
dimensions dimensions
dimensions
of condenser
model to top of
Height Width Depth Height Width Depth Height Width
Depth
refrigerator
A B C h
W
d H
W D e
RM360
30 3/8
21 11/16 22 1/16
29 9/16
20 1/4
20 3/16 29 3/4
20 1/2
21 3/16
1 1/4
RM460
32 15/16 23 24 11/16 32 1/8
21 9/16
22 3/4
32 5/16 21 13/16 23 3/4
1 1/4
RM660
40 13/16 23 24 11/16 40 21 9/16
22 3/4
40 3/16 21 13/16 23 3/4
1 1/4
RM760
52 23 24 11/1
51 3/16
21 9/16
22 3/4
51 3/8
21 13/16 23 3/4
1/8
Storane volumes
Refrigerator Total storage volume in cu ft
model
RM360
3.0
RM460
3.9
RM660
5.1
RM760
6.0
EXAMPLES
The clearance N for the RM360 model is derived
in the following way:
at
A. Installation with upper and lower side vents.
N=Minimum ventilation height 37 minus in-
stallation height 29 9/16 plus distance
between condenser top and refrigerator top
1 l/4
N=37-29 9/16+1 l/4=8 11/16.
B. Installation with roof vent and lower side
vent.
N=Minimum ventilation height 31 minus in-
stallation height 29 9/16 plus distance
between condenser top and refrigerator top
1 l/4 plus distance between roof surface
and roof vent cap 5 l/4.
N=31-29 9/16+1 l/4+5 l/4=7 15/16.
Fig.6