14
Replacement of gas/electric equipment complete
1. Remove the covers by removing the screws (1).
2. Disconnect the heater cords at the terminal
blocks (note the locations for later relocation).
3. Remove the capillary tube carefully from the
evaporator.
4. Remove the screws (2).
5. Release the burner housing from the flue by
turning the lever (3) as shown.
6. Pull the equipment out from the cabinet.
Fig.21
115v
220v
240v
_12V
Disassembly of gas electric/equipment
1.
2.
3.
4.
5.
6.
7.
Press the plastic latch (leftwards
in Fig. 22).
Pull the relay out (if any).
Snap off the fuse holder.
Press the spring.
Pull the shut-off valve out.
Press the gas/electric thermostat left-
wards and lift it out.
Unscrew the thermocouple from the flame
failure safety device.
8. Press the retaining spring for release of
thermocouple.
9. Pull out the thermocouple leftwards.
10. Pull the flame failure safety device left
and lift it out.
11. Pull off the ignition cord.
12. Snap off the retaining spring.
13. Pull out the igniter.
NOTE:
When assembling, always use new
O-rings
for the joints.
2
Fig.22
Summary of Contents for RM360