Fastening the inverter
You can fasten the inverter using the four holders supplied.
When selecting the installation location, observe the following instructions:
•
The inverter can be mounted horizontally or vertically.
•
The inverter must be installed in a place that is protected from moisture.
•
The inverter may not be installed in the presence of flammable materials.
•
The inverter may not be installed in a dusty environment.
•
The place of installation must be well-ventilated. A ventilation system must be
present for installations in small, enclosed spaces. The clearance around the
inverter must be at least 25 cm (fig.
4
, page 5).
•
The air intake on the underside or the air outlet on the back of the inverter must
remain clear.
•
For ambient temperatures higher than 40 °C (such as in engine or heating com-
partments, or direct sunlight), the heat from the inverter under load can lead to
the automatic shut-off of the inverter.
•
The installation surface must be level and sufficiently sturdy.
A
Fasten the inverter as follows (fig.
5
, page 5):
➤
Clip two holders on the lower left bar and two on the right.
You can move the holders as required.
➤
Fasten the inverter by screwing one screw through each hole in the holders.
NOTICE!
The cable between the battery and the inverter may not exceed a
maximum length of 2 m.
NOTICE!
Before drilling any holes, ensure that no electrical cables or other parts
of the vehicle can be damaged by drilling, sawing and filing.
PP150-PP400-PP600--IO-16s.book Seite 11 Mittwoch, 18. Januar 2017 1:13 13
Summary of Contents for PERFECTPOWER PP152
Page 2: ......
Page 3: ...PerfectPower 3 POWER FAULT 4 5 1 2 3 4 5 1 2 3 PP152 PP154 PP402 PP404 PP602 PP604 1...
Page 5: ...PerfectPower 5 A B 3 N EG RE VE RS E PO LA RI TY CH AS SIS P 25 cm 25 cm 4 1 2 5...
Page 145: ...RU PerfectPower 145 1 A I 2 2 1...
Page 146: ...RU PerfectPower 146 2 2 230 12 24...
Page 147: ...RU PerfectPower 147 2 3 60 C 230 1 1 3 230...
Page 150: ...RU PerfectPower 150 6 A 6 1 25 4 5 40 C A 5 5 2...
Page 153: ...RU PerfectPower 153 10 8 PP152 PP402 PP602 21 5 PP154 PP404 PP604 1 2 3 1 2 3 8 2 3 4 9 A...
Page 154: ...RU PerfectPower 154 10 11 PP152 PP154 12 24 10 8 PP152 PP402 PP602 21 5 PP154 PP404 PP604...