EN
SinePower
Connecting the inverter
17
8.3
Mounting the inverter
➤
Hold the inverter against the installation location and mark the fastening points
(fig.
3
A, page 4).
➤
Attach the inverter using your chosen fastening method (fig.
3
B, page 4).
9
Connecting the inverter
9.1
General instructions
!
•
When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
•
When setting up a socket distribution circuit (mains setup), comply with the appli-
cable regulations.
•
Only use copper cables.
•
Keep the cables as short as possible (< 1 m).
•
Keep to the specified cable cross section and fit a cable fuse (fig.
4
3, page 4)
as close to the battery as possible on the positive cable (see the table).
WARNING!
•
The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
•
Never
use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
•
If you do not fit a fuse to the
positive cable
, the cables can over-
load, which might result in a fire.
Device
Required cable
cross section
Cable fuse
MSI2312T
70 mm²
350 A
MSI2324T
50 mm²
175 A
MSI3512T
95 mm²
400 A
MSI3524T
70 mm²
200 A
MSI2300-3500--IO-16s.book Seite 17 Mittwoch, 3. August 2016 5:46 17