8. Customer service

Before you call a service engineer, carry out the
following simple tests:

If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.

(Details of the model, product- and serial-number are

to be found on the data label in the top left of the
inside compartment.)

In the event of a fault developing, contact your
nearest Service Centre-see local telephone
directory.

www.dometic.com

GB

Problem

The appliance does not cool
sufficiently

The appliance does not cool at all.

Possible cause

Too much food to be cooled was put in.

Door is not shut properly.

Internal air circulation is restricted.

CUC system stopped the operation.
Plug is not connected to the mains socket
properly

There is no voltage in the mains socket.

Solution

Put in less food to be be cooled.

Check if the door is shut.

Provide inside cool air circulation.

See operating instruction 5.3.
Check if the connection is
proper.

Check if there is voltage.

Only for UK:

The appliance is supplied with a 3 Amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 3 Amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:

Green and Yellow: Earth

Blue:

Neutral

Brown:

Live

The wire coloured green and yellow must be
connected to the terminal marked with the letter "E"
or by the earth symbol 

or coloured green and

yellow.

The wire coloured blue must be connected to the
terminal "N" or coloured black.

The wire coloured brown must be connected to the
terminal marked "L" or coloured red.

Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.

9. Putting into operation

Technical data:

9.1. Connecting to electrical mains

The appliance may only be operated from
nominal voltage mains as shown on the data

plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with regulations.

Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.

The manufacturer declines any liability should
these safety measures not be observed.

Electrical Requirements

Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.

Model

RH 465LD

Type

MB20-60

Gross volume

34 litres

Mains operation

220 - 240V (AC)

Input

65W

Energy consumption

0,700 kWh/24h

Climate class

N

Refrigerant

147g H2O+98g NH3

* The energy consumption is measured at 12°C at 25°C environment
temperature (cellar).

Summary of Contents for MB20-60

Page 1: ...207 5396 39 RH 465LD Type MB20 60 miniBar Operating Instructions Bedienungsanleitung Mode d emploi Istruzioni per l uso Handleiding Manual de Instrucciones Instru es de Utiliza o FR DE GB IT NL PT ES...

Page 2: ...oduct which heat up Always ensure that there is adequate ventilation as a failure to do this will result in component failure and possible content loss See installation instructions Parts which heat u...

Page 3: ...ed to When contacting Dometic Service Network please state the model product number and serial number You will find this information on the data plate inside of the refrigerator CONTENTS 1 Unpacking 2...

Page 4: ...n firm 2 View of the appliance 1 Door 2 Door lock if available 3 Lamp 4 ADC LED if available 5 Storage Compartment 6 Evaporator cover 7 Evaporator sensor behind evaporator 8 Evaporator 9 Shelves 10 Ai...

Page 5: ...n the underside of the refrigerator Fig 2 In this way you can always move your refrigerator to where it is needed Figure 2 Do not use the refrigerator without installing the wheels because in this cas...

Page 6: ...th a fully automatic electronic temperature regulator The frost will melt and the defrost water will run through the drain tube from the drip channel into an evaporating vessel located at the bottom r...

Page 7: ...ced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live The wire coloured green and yellow must be connected to...

Page 8: ...pliance should be delivered to a specialized collection and reprocessing firm which reclaims the usable materials The rest is properly destroyed Appliances bearing this symbol must be deposited at the...

Page 9: ...ch im Betrieb auf Stellen Sie sicher dass stets ausreichend Luftzirkulation zur Verf gung steht da das Ger t sonst besch digt werden kann und der Inhalt verdirbt Siehe auch Installationsanweisungen He...

Page 10: ...antiebedingungen entsprechen der EU Richtlinie 44 1999 CE und den im jeweiligen Bestimmungsland geltenden Gesetzen Bei Fragen zu Garantie und Kundendienst sowie f r Ersatzteile wenden Sie sich bitte a...

Reviews: