6.6
Installing an external alarm
Use the floating contacts at the back of the device as follows:
•
The upper contacts correspond to the power fail alarm (fig.
9
1 and 2, page 7).
•
The lower contacts correspond to the temperature alarm (fig.
9
3 and 4,
page 7).
A voltage between 12 V and 250 V can be connected at the contacts. The maximum
load must not exceed 8 A. The minimum power rating is 100 mA/5 V.
I
7
Using the refrigerator
I
7.1
Energy saving tips
•
Choose a well ventilated location which is protected from direct sunlight.
•
Do not open the refrigerator more often than necessary.
•
Do not leave the doors open for longer than necessary.
•
Defrost your refrigerator as soon as a layer of ice forms.
NOTE
The external alarm signal can only be switched off by eliminating the
cause of the alarm.
NOTE
•
Before starting your new refrigerator for the first time, you should
clean it inside and outside with a damp cloth for hygienic reasons
(please refer to the chapter “Cleaning and maintenance” on
page 25).
•
Always leave some space between the medicinal products in the
refrigerator to ensure efficient and even cooling. If the drawers are
packed too tightly there may be unacceptable temperature values.
•
Keep these operating instructions ready at hand and leave them with
the device, so that all users can find out about the functions and
safety regulations.
HC302D-502D-IO-WEST.book Seite 20 Freitag, 17. März 2017 2:15 14
Summary of Contents for HC302D
Page 2: ......
Page 3: ...HC302D HC502D 3 2 1 5 7 8 6 HC302DFS HC502DFS HC302DBIU HC502DBIU 3 3 4 1...
Page 4: ...HC302D HC502D 4 5 6 7 8 4 3 1 2 2 1 2 1 1 1 2 2 2 A D C B 3...
Page 5: ...HC302D HC502D 5 50 mm 4 50mm 5...
Page 6: ...HC302D HC502D 6 min 100 6 1 2 3 7...
Page 7: ...HC302D HC502D 7 4 1 1 3 2 8 1 2 3 4 1 2 3 4 9...
Page 8: ...HC302D HC502D 8 C D A B 0 820 422 FS 450 BIU 440 540 580 HC302D a...
Page 9: ...HC302D HC502D 9 HC502D 948 486 FS 494 BIU 484 552 592 b...