Dometic FJX
EN
FreshJet FJX4233M
Required fuse:
4 A
Operating temperature range:
−
2 °C
…
52 °C
Refrigerant:
R410a
Refrigerant quantity:
380 g
CO
2
equivalent:
0.793 t
Global warming potential
(GWP):
2088
Protection class (roof top unit):
IPX4
Noise level (highest fan set-
ting)
<
70 dB(A)
Suggested max. vehicle
length (with insulated walls):
<
5 m
Dimensions L x W x H:
fig.
l
Weight:
<
30 kg
Inspection/certification:
FreshJet FJX4233EEH
FreshJet FJX4333EEH
FreshJet FJX4333E
Cooling capacity based on
ISO 5151:
1700 W
2200 W
2200 W
Heating capacity based on
ISO 5151:
800 W
1000 W
–
AC Input voltage:
220 V
…
240 V / 50 Hz
Rated current cooling:
3.6 A
4.8 A
4.8 A
Rated current heating:
<
5.2 A
<
5.2 A
–
Required fuse:
4 A
5 A
6 A
Operating temperature range:
−
2 °C
…
52 °C
Refrigerant:
R32
Refrigerant quantity:
320 g
360 g
360 g
CO
2
equivalent:
0.216 t
0.243 t
0.243 t