Electrical connection
23.Connect the power supply cable.
a) Connect the cables (
1
) to a cable connector (
2
).
b) Connect the roof air conditioner with the power supply.
c) Connect the grounding cable to the vehicle's grounding system.
24.
Only FreshJet FJX4233M:
Connect the cable between the external unit and the air box diffuser.
a) Pull out the filter slightly to create a gap for the communication cable (
3
).
b) Feed the cable through the gap and locate the wire in the opening.
c) Connect the communication 6-pin plug into the socket on the side of the display in the ADB. Ensure that the cable
is located into the small opening away from the filter area.
d) Secure excess cable into the holders.
25.
Only FreshJet FJX4233EEH/FJX4333E(EH)/FJX7333IHP/FJX7337IHP/FJX7457IHP:
Connect the com-
munication cable.
a) Pull out the filter slightly to create a gap for the communication cable (
4
).
b) Feed the communication cable through the gap and locate the wire in the opening.
c) Connect the communication 4-pin plug into the socket on the side of the display in the ADB. Ensure that the cable
is located into the small opening away from the filter area.
d) Secure excess cable into the holders.
Installing the ADB
26.Stack the duct sections and place against the roof thickness: Ensure that the duct height matches the roof height
or use the table as guide.
Roof thickness
Number of duct sections
25
…
35 mm
1
35
…
45 mm
2
45
…
55 mm
3
55
…
60 mm
4
Note
Additional duct sections can be purchased for thicker roofs.
27.Attach the required number of duct sections on the ADB.
28.Fasten the ADB to the ceiling through the roof top unit with the 4 bolts supplied. Tighten the screws using a
torque spanner and a fastening torque of 2.5 Nm ±
0.3 Nm.
29.Push the filter back fully in.
30.Clip the center cover to the ADB.
19
Summary of Contents for FJX4233EEH
Page 4: ...EN Dometic FJX 3 1 4 2 5 A 1 3 2 2 ...
Page 5: ...Dometic FJX EN 6 4x 1 2 4x 7 1 2 A B 8 1 2 9 0 3 ...
Page 6: ...EN Dometic FJX a BUTYL 1 2 b 4 ...
Page 8: ...EN Dometic FJX d FJX4233M FJX4233EEH FJX4333E EH FJX7333IHP FJX7337IHP FJX7457IHP 6 ...
Page 11: ...Dometic FJX EN i j 9 ...
Page 216: ...4445103467 4450028838 54 906 MAM01A 2022 06 29 ...