6 .4 Mounting the Display Panel
MA DISPLAY
CA DISPLAY
J1
JP5
CW
EMBLE
SEL
RES
LPF
EMBL
E
JP1 JP2
JP3
DC
PRESS SWT
HP
LP
JP4
AUX HEAT
GATE
TRM-1
JP6
PSNB
JP8
VSNB
COMP
L2
FAN
L2
PUMP
L2
COMP
L1
L1
L2
VALVE
L1
FAN
L1
PUMP
L1
J2
J3
P4
P5
P6
INSIDE
H20
IN
H20
OUT
OAT
6
Plugging in the Display Cable
1. Plug the display cable 8-pin connector into the
upper-right jack on the circuit board.
2. Insert the other end of the display cable into the
display jack on the back of the display panel.
q
w
e
r
7
Securing the Display
q
Cutout
e
Bezel
w
Display Panel
r
Screw
3. Use the four screws provided to secure the display
panel to the bulkhead. Do not use a screw gun or
overtighten the screws.
4. Snap the bezel onto the display panel frame.
6 .5 Testing the Display
NOTICE:
For DX units only: do
not
turn the circuit
breaker or power supplied to the unit OFF and then
immediately turn it back ON. Allow at least five minutes
for the refrigerant pressure to equalize. Failure to obey
this notice could result in damage to the air conditioning
unit.
1. Open the seawater-intake ball valve (seacock).
2. Turn the display OFF. Wait a minimum of five minutes.
3. Turn the air conditioner circuit breaker ON.
I
If the seawater pump is on a separate circuit
breaker, be sure to turn it ON.
4. Turn the display ON.
5. Press the
Fan
button.
6. Verify that the fan is running and that a steady airflow
is coming out of the supply-air grille.
7. Select a temperature set point lower than the current
cabin temperature.
8. Verify that a steady, solid stream of water is coming
out from the overboard discharge.
9. Verify that a steady airflow is continues to flow out of
the supply-air grille.
I
If the unit is not functioning as expected, refer to
“Troubleshooting” on page 25.
7 Operation
NOTICE:
If the unit is cool-only, change parameter P-33
to CL, then select AUTO mode. Do
not
set the unit to
AUTOMATIC mode before changing parameter P-33 to
CL. Cool-only units do
not
heat unless equipped with
auxiliary heating. Failure to obey this notice will cause
the unit to cool in both modes. Refer to “Selecting a
Parameter” on page 16.
I
When used with optional auxiliary electric heater,
the fan remains ON for four minutes after the heater
cycles OFF, even if the fan is set to cycled operation.
I
The images in this section show the Elite Control
display, unless otherwise indicated.
This section describes the cycle, programming, and
functions for the Elite Control.