Initial Operation
The device must be plugged into a properly
earthed socket.
The miniCool achieves its operating
temperature after several hours.
INSTRUCTION FOR USE
Temperature Control
The miniCool is fitted with an electronic
temperature control. The thermostat
control button is situated in the internal
containers rear area. (EA 355: the
thermostat button is situated in the
unrefrigerated compartment).
Automatic Defrost Function
The first defrosting phase commences 15 hours after the initial operation
(5.1) and lasts for two hours.
After this, the device operates for 22 hours at a time, followed by a
defrosting period of 2 hours .
The ice layer must never be removed using
force, nor must the defrosting process ever
be accelerated using a heater.
S
T
T
The miniCool operates silently !
T
T
T
T
S
Leakage Detection
Air sensor
The electronics carries out a leakage test after
every defrosting period ( every 24 hrs) by
measuring the temperature at the evaporator
by means of a second sensor.
If a leakage is detected, the miniCool is shut
off by the electronics.
Evaporator sensor