background image

INTRODUCTION

You have made an excellent choice by choosing the 

Dometic miniCool

.

We are convinced that you will be satisfied with your new appliance in every 

way. Silent in operation, the miniCool fulfils high quality standards and 
guarantees an efficient use of resources and energy during its entire working 

life, i.e. during manufacturing, use and disposal. Please study the installation 

and operating instructions carefully before attempting to operate the miniCool.

FOR YOUR SAFETY

Warnings and Safety Advice

Ÿ

In the interests of children's safety:

When disposing of the refrigerator, remove all doors and leave the 

shelves inside. This prevents children from being accidentally trapped or 

suffocated in the refrigerator.

Ÿ

Never open the cooling unit - it is under high pressure.

Ÿ

Never store explosive substances, such as lighter fuel, petrol, ether or 

similar products in the miniCool.

Ÿ

The minibar is not suitable for the proper storage of medications.

Ÿ

The miniCool must be installed in such a way that accidental contact with 

the cooling unit (which heats up when in use) is impossible.

Ÿ

The appliance has to be connected to a properly earthed socket in line 

with the relevant valid country regulations.

Ÿ

Servicing must only be carried out by authorised service personnel.

Coolants

Ammonia is used as the coolant. This is a natural compound which is also 

present in common household cleaners (1 litre of salmiac cleaner contains 

up to 200g of ammonia - this is roughly double the amount contained in the 

cooling unit).

If a leak occurs (which can be easily detected due to the unpleasant smell):

Ÿ

Switch the device off (pull mains plug, if applicable);

Ÿ

Ventilate room thoroughly.

Ÿ

Inform hotel personnel.

For the safety of hotel guests and personnel, it has been established by

inspectors that the coolant poses no threat to health.

WARRANTY AND CUSTOMER SERVICE

Warranty arrangements are in accordance with 

EC Directive 44/1999/CE and 

the normal conditions applicable for the country concerned.

For warranty or service, please contact our customer services  section.

Spares can be obtained all over Europe from our relevant customer service 

points.

When contacting customer service, please always state model, product and 

serial number! You can find this information on the model label inside the 

device.

3

11..00

22..00

2.1

33..00

2.2

e.g.

All manuals and user guides at all-guides.com

Summary of Contents for EA 330

Page 1: ...Type H20 60 821 2675 51 T D 07 2003 English miniCool INSTRUCTION for USE ABSORPTION REFRIGERATOR EA 330 L EA 355 L All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...ng the Device to the 6 Electricity Supply 4 8 Changing the Sliding Hinge 7 4 9 Changing the Doorhang 8 5 0 INSTRUCTION FOR USE 9 5 1 Initial Operation 9 5 2 Temperature Control 9 5 3 Automatic Defrost...

Page 3: ...he appliance has to be connected to a properly earthed socket in line with the relevant valid country regulations Servicing must only be carried out by authorised service personnel Coolants Ammonia is...

Page 4: ...ltage Depending on the model the following parts can be found in the miniCool Cleaning Before operating the miniCool we recommend you clean it both inside and outside Use a soft cloth lukewarm water a...

Page 5: ...e cooling unit must project into the duct as shown 6 Air passing through the duct must not be preheated by any source of heat 7 Ventilation grills if used must have openings of at least 200cm each Ple...

Page 6: ...with other plug types the circuit should contain a 5 amp fuse This appliance conforms with the requirements of EEC directive No 82 449 relating to radio interference Warning This appliance must be ear...

Page 7: ...ase of the plug In no circumstances must the plug be used without a correct fuse cover carrier fitted If the plug supplied on the mains lead is not suitable for the socket in your home it should be cu...

Page 8: ...8 Changing the Doorhang possible with EA 330 1 2 3 4 5 6 7 8 9 10 11 R 12 13 R L L 4 9 1 2 1 2 All manuals and user guides at all guides com...

Page 9: ...efrosting phase commences 15 hours after the initial operation 5 1 and lasts for two hours After this the device operates for 22 hours at a time followed by a defrosting period of 2 hours The ice laye...

Page 10: ...mechanism an electric circuit is closed or opened Accordingly this is registered and processed at the hotel reception Note Electrical rating The miniCool wiring connection is situated at the rear of...

Page 11: ...a sensor Changing 11 5 6 To obtain spare bulbs please contact your Dometic Service Centre 1 Pull out the mains plug 2 Press out reflector disk 3 Remove defective LED board 4 Insert new LED board 5 Cl...

Page 12: ...a disposal company or local council which will guarantee the correct use of recyclable materials and the proper disposal of the rest Energy Saving Tips At an average room temperature of approx 22 C i...

Page 13: ...run for 5 6 hours c Check whether repair is feasible If not exchange device Problem Poor Cooling Performance Possible Cause Self Help Authorised Service a The cooling aggregate is not sufficiently ve...

Page 14: ...65 Power Consumption kWh 24h 0 7 0 8 Net Weight Kg 11 26 Power consumption measured at an average ambient temperature of 25 C as an average annual value and at a cooling compartment temperature of 7...

Page 15: ...ect to change without notice Printed in Germany Dometic GmbH In der Steinwiese 16 D 57074 Siegen Phone 49 0 271 692 0 Fax 49 0 271 692 300 www dometic de minibar www dometic com All manuals and user g...