background image

7

6. ICE CUBES

Fill the ice tray to 4/5 with drinking water, cover with

the  lid  and  place  the  closed  ice  tray  on  the  ice-tray

shelf. Wipe off any excess water to prevent the ice tray

from freezing to the surface.

To  speed  up  the  making  of  ice  cubes,  turn  the

thermostat to position 5 for a short while. Remember

to turn the dial to its normal setting when the ice cubes

are frozen.

To remove the cubes from the ice tray, hold it under

running water. Remove the lid with the ice cubes from

the ice tray and the ice cubes can now be taken out

easily.

7. Useful suggestion

Do not overfill the appliance. It is advisable to leave

some space between the products in the cabinet to

ensure efficient and even cooling. If the shelves are

packed  too  tightly  there  may  be  unacceptable

temperature variations.

8. Defrosting, cleaning and

maintenance

Frost will gradually form on the cooling surfaces and it

must not be allowed to become too thick since it acts

as an insulator and interferes with the cooling.

This frost-formation is kept back by the FUZZY LOGIC

system built into the appliance by switching off the unit

for two hours in every 24 hours. The frost will melt and

the defrost  water will run through the drain tube from

the drip channel into an evaporating vessel located at

the bottom rear of the refrigerator. (Fig 5) The defrost

water will evaporate automatically into the circulating

air and the vessel will not need emptying manually.

If we want to switch off the unit, turn the thermostat

knob  to  "0",  disconnect  the  refrigerator  from  the

electricity  supply  and  leave  the  cabinet  door  open.

After defrosting the cabinet interior should be wiped

out with a clean, damp cloth.

9. Changing the lightbulb 

(If available)

If the lightbulb needs changing, pull out the plug and

proceed as follows:

Press  the  metal  reflector  to  one  side  and  draw  the

lamp covering backwards. Replace the bulb and push

the covering back into place.

A new 10-watt bulb can be obtained at any  service

shop.

10. Reversing the door hang, Fig. 6

Lay the appliance on its back. Remove the 8 screws

(1).  Remove  the  door,  together  with  the  two  hinges

(2), from the housing.

Remove the two cover caps (3) from the housing and

place  them  in  the  open  hinge  holes  in  the  housing.

Place the bottom righthand hinge in the top left of the

door and the top righthand hinge in the bottom left of

the door and hang the door on its hinges in the open

Figure 5.

Figure 6.

Summary of Contents for EA 3080

Page 1: ...207 5166 20 EA 3100 EA 3080 EA 3140 RA 80 RA 140 RH 200 miniCool J Operating Instructions ...

Page 2: ...ent failure and possible content loss See installation instructions Parts which heat up should not be exposed Wherever possible the back of the product should be close to a wall but leaving the required distance for ventilation as stated in the installation instructions Before defrosting cleaning or maintenance work is carried out be sure to switch off the appliance and unplug it DO NOT USE SHARP ...

Page 3: ...ulation 6 Ice cubes 7 Useful suggestions 8 Defrosting cleaning and maintenance 9 Changing the lightbulb 10 Reversing the door hang 11 Replacing the decorative door panel 12 Assembly of door handle 13 Changing the feet 14 Customer service 15 Putting into operation technical data 15 1 Connecting to electrical mains 16 Environmental protection information 17 Recycling ...

Page 4: ...port it immediately to the transportation firm 2 View of the appliance 1 Door lock 2 Sensor 3 Thermostat knob 4 Evaporator 5 Lamp if available Figure 1 IN CASE IF YOUR REFRIGERATOR IS EQUIPPED WITH LOCK DOMETIC RT DO NOT ACCEPT LIABILITY FOR LOSS OR DAMAGE OF KEYS HOWEVER WE WOULD BE HAPPY TO SUPPLY A COMPLETE LOCK AND KEY REPLACEMENT EA 3100 EA 3080 EA 3140 ...

Page 5: ...tion process the appliance gives off heat from the condenser under the upper part of the rear cover into the surrounding air The more ventilated the condenser is the more effective the refrigeration will be The other condition for satisfactory operation is that the appliance stands on a flat surface This is best seen by placing a glass of water on top of the appliance It is important that the appl...

Page 6: ...socket outlet and switch on the socket The cooling fins should show signs of cooling after about 3 hours The refrigerator needs about 6 hours at normal ambient temperature to reach 6 C in the storage compartment 5 1 Temperature regulation The usual setting required is in the region of 2 to 3 on the thermostat knob Fig 4 but this can vary with conditions of load and installation If it is found nece...

Page 7: ...nit for two hours in every 24 hours The frost will melt and the defrost water will run through the drain tube from the drip channel into an evaporating vessel located at the bottom rear of the refrigerator Fig 5 The defrost water will evaporate automatically into the circulating air and the vessel will not need emptying manually If we want to switch off the unit turn the thermostat knob to 0 disco...

Page 8: ...ge 5 Slide the decorative panel 6 out of the door frame and insert the new panel 7 so that the upper edge of the panel runs exactly parallel to the upper edge of the frame A new panel can be inserted more easily into the upper edge of the frame when the two corners are cut off by approx 5 x 5mm 8 Put the frame edge 5 back in place and secure with screws Place the door on the lower hinge 9 slot the...

Page 9: ...ator level Has the ventilation become obstructed If after checking all the above points the refrigerator is still not working satisfactorily contact your nearest service engineer State the problem model product and serial number Details of the model product and serialnumber are to be found on the data label in the top left of the inside compartment This refrigerator is equipped with overheating pr...

Page 10: ...ironmental protection information The appliance does not contain any CFCs HCFCs Ammonia natural hydrogen and nitrogen compound is used as a refrigerating agent in the refrigeration unit The ozone friendly cyclopentane is activated as a motive agent for the PU foam insulation Sodium chromate is used for corrosion protection less than 2 weight of the coolant 17 Recycling After unpacking the applianc...

Page 11: ...11 ...

Page 12: ...Printed by Xerox Hungary Ltd Rev 2003 08 07 ...