7
6 Installation
1 . Select panel location away from direct contact with
water and oil .
2 . Confirm clearance for wire connections behind wall,
hull liner or bulkhead .
3 . Using control panel template (fig . 8 , page 11), cut out
panel access hole (E, F) and drill fastener holes (G) .
4 . With electrical power off, route 14-gauge stranded copper
wire from power source, through discharge pump circuit
breaker or fuse (not provided), to panel location . Route
additional wire according to diagram on page 3 or 4
(see wiring diagram keys below), depending on your
application, to panel location . Make sure wires extend
out through access hole .
5 . Make proper wiring connections to wires extending from
bottom of circuit assembly (fig . 2 4, page 2) .
6 . Remove panel cover (fig . 2 1, page 2) from mounting
frame (2) by carefully pulling them apart . Make sure wires
between key switch (3) and circuit assembly (4) remain
attached . (Key pin 1 – red; pin 2 – brown; pin 7 – blue .)
7 . Install mounting frame to wall with four fasteners (5) .
8 . Tuck key switch wires into circuit assembly housing,
and push panel cover onto mounting frame until it
locks into place .
9 . Turn on electrical power .
6.1
Tank Discharge Control Panel
(fig . 2 , page 2)
Control Panel Template
Dimensions
(fig . 8 , page 11)
2
Dometic Tank Discharge Control
Specifications
Caution!
Do not install DTD control panel in an atmosphere with potentially flammable or
explosive vapors.
Ref.
Dimension
A
83 mm (3 .25 in .)
B
83 mm (3 .25 in .)
C
67 mm (2 .63 in .)
D
67 mm (2 .63 in .)
E
55 mm (2 .16 in .)
F
68 mm (2 .69 in .)
G
2 mm (0 .10 in .) dia .
H
Cut-out area .
Allow 51 mm (2 in .)
clearance behind wall .
8
8
2
2
ISO8846; EMC Directive 2004/108/EC
5.4 Approvals
5.3 Dimensions
(fig . 3 , page 2)
Ref.
Dimension
A
83 mm (3 .25 in .)
B
83 mm (3 .25 in .)
3
Ref.
Dimension
C
51 mm (2 in .) clearance behind wall
D
10 mm (0 .38 in .)
Maximum relay rating for 12 or 24 V DC discharge pump: 20 amps .
Float Switch Rating: 20 watts with resistive load (when used with DTM04 system) .
Summary of Contents for DTD01
Page 2: ...2 Dometic Tank Discharge Control 1 1 2 3 4 5 6 7 2 4 5 3 1 3 2 A B C D ...
Page 3: ...3 1 2 3 4 5 Dometic Tank Discharge Control ...
Page 4: ...4 Dometic Tank Discharge Control 1 2 4 3 6 7 ...
Page 11: ...11 Dometic Tank Discharge Control Installation template 8 A C H G F B D E ...
Page 12: ...12 Dometic Tank Discharge Control Installation template ...
Page 50: ...50 Dometic säiliön tyhjennysohjaus rekisteröity Dometic Corporationin tuotemerkki ...
Page 56: ...56 Dometic styrning för tanktömning Registrerat varumärke från Dometic Corporation ...
Page 62: ...62 Dometic tankudledningsstyring registreret varemærke fra Dometic Corporation ...
Page 68: ...68 Dometic styreanordning for tømming av tank registrert varemerket til Dometic Corporation ...
Page 69: ...69 ...
Page 70: ...70 ...