20
C.
Absorption System Ignition Error
This error applies to the upper food compartment. The control panel LED illuminates when an ignition error occurs.
See (FIG. 2) & (Table 9).
See “Controls” on page (7) for more information.
Table 9
(D)
LED
Description
AMBER
(Steady)
●
Check LP gas (LP gas did
NOT
ignite). See “B. Modes Of Operation” on page (9).
●
LP gas (supply) bottle may be empty. Replace (supply) bottle.
●
Air may be trapped in gas line. See “A. Purge LP Gas Lines” on page (10).
D. Compressor System Error Codes
These error codes apply to the lower food compartment. The control panel LED flashes when certain errors occur.
See (FIG. 3) & (Table 10).
See “Controls” on page (7) for more information.
Table 10
(J)
LED
(K)
LED
(L)
LED
Number Of
Flashes
Description
AMBER
(Flashing)
N/A
N/A
1
●
Battery voltage is outside normal operating range. Check battery.
Lower compartment shuts down under this condition if 120 Vac
power is also
NOT
available.
2
●
Compressor fan overload. Foreign object(s) may be obstructing fan
blades from spinning.
3
●
Compressor system (motor start error).
●
Contact a Dometic dealer or Service Center for repair.
4
●
Compressor system (motor speed error).
●
Contact a Dometic dealer or Service Center for repair.
5
●
Thermal shutoff (Compressor controller is too hot). Compressor
system restarts automatically when temperature is within normal
operating range.
●
If problem persists, contact a Dometic dealer or Service Center for
repair.
N/A
BLUE
(Flashing)
BLUE
(Flashing) Continuous
●
Temperature in lower food compartment is outside normal operating
range. Compressor system continues to operate in standby mode
until temperature returns to normal operating range.
●
If problem persists, contact a Dometic dealer or Service Center for
repair.
APPENDIX A: TROUBLESHOOTING