The operator is responsible for having the necessary inspections conducted. S/he must be 
notified in writing of the inspection requirement by the technician who installs the appliance.  
 
The appliance may be used only for cooking, baking and grilling under the conditions 
specified elsewhere in these instructions. Under no circumstances may it be used for other 
purposes (e.g. heating, etc.).  
 
Use of the appliance can result in the accumulation of humidity or heat in the installation 
location. Make sure that the kitchen is well-ventilated: keep the normal ventilation openings 
open or provide for a mechanical ventilation device.  
 
Intensive or prolonged used of the appliance may require additional ventilation, e.g. opening a 
window or operation of the mechanical ventilation device at a higher setting.  
 
A sign must be fitted above the cooker, stating that the closable vent must be opened while 
the cooker is in use, and that the burners must not be used for heating.  The sign must be 
clearly visible. 

 

IMPORTANT: 

When using gas kitchen appliances, the closable vents in the installation 

location must be open. Naked burners must not be used for heating! 
 

IMPORTANT: THE APPLIANCE MUST BE INSTALLED BY AN AUTHORIZED 
TECHNICIAN IN ACCORDANCE WITH THE APPLICABLE STANDARDS (EN 
1949).

 

THE ELECTRIC COMPONENT (IN THE CASE OF THE COE … DUFU MODELS) 
MUST BE INSTALLED BY AN AUTHORISED TECHNICIAN IN ACCORDANCE 
WITH THE APPLICABLE REGULATIONS (IN PARTICULAR EN 60335, EN 1648). 

IMPORTANT: TO PREVENT ANY RISK OF ACCIDENT, IT IS NECESSARY THAT 
THE APPLIANCE BE INSTALLED ACCORDING TO THESE INSTRUCTIONS. 
IMPROPER INSTALLATION WILL VOID THE WARRANTY. 
“ANY MODIFICATION TO THE APPLIANCE MAY BE DANGEROUS AND IS 
PROHIBITED!” 

1.  ROOM VENTILATION 

Any room in which one or more appliances are to be installed must have one or more vents 
enabling fresh air to enter. One or more vents must be located above the appliance to 
ensure sufficient disposal of combustion products and sufficient fresh air supply for the 
user. 
These vents must comply with the requirements specified in the EN 1949, EN 1646-1 and 
EN 721 standards. 
The user must check and, if necessary, clean these vents from time to time (for example, 
they must be cleaned of snow or slush during the winter). 
 
 
 

Summary of Contents for COE-C

Page 1: ...Cooker grill oven 4 gas burners COE FULL Cooker grill oven pot store 4 gas burners COE C DUFU Cooker 3 gas burners 1 electric burner COE CG DUFU Cooker grill 3 gas burners 1 electric burner COE CGO D...

Page 2: ...e of the appliance The appliance fitter must hand these operating instructions to the user We recommend concluding a service contract If the gas tap becomes sluggish or jammed then it must either be r...

Page 3: ...sing gas kitchen appliances the closable vents in the installation location must be open Naked burners must not be used for heating IMPORTANT THE APPLIANCE MUST BE INSTALLED BY AN AUTHORIZED TECHNICIA...

Page 4: ...n of bubbles IMPORTANT DURING INSTALLATION AND CONNECTION OF THE APPLIANCE MAKE SURE THAT THE GAS INLET PIPE IS NOT TWISTED PULLED OR OTHERWISE STRAINED 3 GAS CYLINDERS Use gas cylinders that are comm...

Page 5: ...pth of at least 325 mm and a height of at least 620 mm 4 VISUAL CHECK OF FLAME a The flame must burn steadily It must be primarily blue and display clear contours b If the flame does not burn steadily...

Page 6: ...H THE APPLICABLE REGULATIONS NEVER CONNECT THE 12 V DC CONNECTION TERMINAL TO THE 230 V AC MAINS NETWORK THIS WOULD NOT ONLY DESTROY THE ELECTRICAL AND ELECTRONIC COMPONENTS BUT WOULD ALSO ENDANGER TH...

Page 7: ...on the individual model see type plate on appliance Fig 1 The installation location is limited only as follows The appliance must rest on a firm and stable base with mounted in the cabinet The applia...

Page 8: ...is used the distance between it and the side moveable wall must be at least 3 mm In that event the minimum distance between the burner edge and the moveable wall is 100 mm In respect of the COE applia...

Page 9: ...shatter if heated Turn off all burners before closing the lid If the burners gas outlet openings are dirty or blocked they must be cleaned The thermal element must be clean and care must be taken to m...

Page 10: ...elease the knob and turn to the required setting The grill may only be operated at the high setting The grill door may be open or closed while the grill is in use The grill and the oven can also be us...

Page 11: ...ERATING THE GRILL Light the grill burner while the door is fully open CAUTION The appliance will become very hot when in use Keep children away 10 APPLIANCE FAULTS Consult a specialist technician in t...