Important
This appliance is a class 3 appliance intended for installation in a kitchen unit.
Output of the hob (Hs)
4 x 1.6 = 6.4 kW
(Mn = 465 g/h, propane/butane)
or, in the case of the DUFU (dual fuel) model:
Output of the hob (Hs)
3 x 1.6 = 4.8 kW
(Mn = 465 g/h, propane/butane)
1 x 800W (230V AC / 3.5 A)
Output of the grill (Hs)
1.4 kW
(Mn = 100 g/h, propane/butane)
Output of the oven (Hs)
1.1 kW
(Mn = 80 g/h, propane/butane)
The appliance requires 12 V DC to power any internal light and the timed spark ignition.
The pressure regulators used between the gas cylinder and the appliance must comply with
the categories in the following table:
Appliance category Supply pressure
Gas
I
3+
28-30/37 mbar
butane/propane
I
3B
30
mbar
butane
I
3B/P
28-30 mbar
butane/propane
I
3B/P
30 mbar
butane/propane
I
3P
28-30 mbar
propane
I
3B
50
mbar
butane
I
3B/P
50 mbar
butane/propane
It is also possible to operate a 30 mbar appliance in campers with a 50 mbar gas system,
but
only if a 50/30 mbar primary pressure regulator is pre-fitted. ! !
The user must read these operating instructions to familiarise himself/herself with use of the
appliance. The appliance fitter must hand these operating instructions to the user. We
recommend concluding a service contract.
If the gas tap becomes sluggish or jammed, then it must either be replaced or the affected tap
removed from the chamber, cleaned in benzene and lubricated with a special gas tap grease,
e.g. type "Staburgas no. 32" from the Klüber company in Munich. This work must be carried
out by a professional gas technician.
The appliance must be installed by an authorized technician! Particular attention must
be paid to the EN 1949 standard in addition to the usual regulations!
This appliance must be installed and connected according to the applicable installation
conditions. Special attention must be paid to suitable ventilation.
Before connecting the appliance, ensure that the local conditions (gas type and gas pressure)
match the appliance settings. The gas type and gas pressure for this appliance are indicated on
an information label (or on the identification plate).
Gas-bearing parts and the connected exhaust lines (waste gas pipe) must be inspected by an
expert before the initial start-up and at intervals of 2 years in accordance with the applicable
standards, in particular EN 1949 (in Germany also in accordance with DVGW Worksheets G
607 and G 608).