Installing and connecting the extractor hood
➤
Push the air outlet hose (fig.
7
1, page 5) on the air outlet adapter into the
extractor hood (fig.
7
2, page 5).
➤
Fix the air outlet hose onto the air outlet adapter with a cable binder.
➤
Remove the filter.
➤
Lift the extractor hood into the required position and guide the air outlet hose
and the connection cable through the hole in the wall-mounted cupboard.
➤
Secure the extractor hood with four screws (fig.
8
, page 6).
To do this, use screws with the following size:
–
Diameter 4 mm
–
Length according to the thickness of the wall-mounted cupboard
➤
Replace the filter.
➤
Connect the connection cable to the DC power supply.
Make sure the polarity is correct.
6.4
Completing the air outlet guide
➤
Lubricate and clean the area around the roof opening.
➤
Apply the upper part of the mushroom vent with a permanently elastic sealing
material (e.g. Dekalin) (fig.
9
, page 6).
➤
Place the upper part of the mushroom vent into the roof opening.
➤
Push the air outlet hose onto the lower part of the mushroom vent (fig.
0
,
page 7).
➤
Fix the air outlet hose onto the lower part of the mushroom vent with a cable
binder.
➤
Push the lower part of the mushroom vent into upper part (fig.
a
, page 7) from
the inside.
➤
Secure the lower part of the mushroom vent with three screws.
To do this, use screws with the following size:
–
Diameter 4 mm
–
Length = roof thickness – 10 mm
➤
Fix the air outlet hose with the adhesive socket (fig.
4
1, page 4) and cable
binders at suitable places.
CK500-IO-16s-.book Seite 15 Donnerstag, 1. Dezember 2016 11:22 11
Summary of Contents for CK500
Page 2: ......
Page 3: ...CK500 3 1 2 3 4 5 6 1 1 2 3 4 5 6 7 2 2 1 3 ...
Page 4: ...CK500 4 1 4 A B 5 ...
Page 5: ...CK500 5 234 5 189 5 6 2 1 7 ...
Page 6: ...CK500 6 8 Ø 75 80 ø 1 1 0 1 2 9 ...
Page 7: ...CK500 7 1 2 0 a ...
Page 183: ......