33
Dometic CA1000
Installation
7.3.5
Menu level 4: Space factor
The space factor (03 to 20) affects the power levels of the compressor
and fan in automatic mode. If the space to be cooled is very large, select
a higher space factor:
➤
Start configuration mode (see chapter “Start and end configuration
mode” on page 31).
✓
The first digit of the display (fig.
e
5, page 6) shows the menu level
and the second and third show the parameter which can be set.
➤
Press the
+
button (fig.
e
6, page 6) three times to switch to menu
level 4.
➤
Press the
Mode
button (fig.
e
4, page 6) to change the parameter.
✓
The digits in the display flash until the parameter you enter is con-
firmed.
➤
Use the
+
and
–
buttons (fig.
e
6 and 7, page 6) to select the temper-
ature (in °C) with which the system starts.
➤
Press the
Mode
button (fig.
e
4, page 6) to confirm your entry.
✓
The set value is saved and is then used when the system is restarted.
✓
You are now in menu level 4 and can use the
+
and
–
buttons to switch
between menu levels.
7.3.6
Menu level 5: Default setting
You can return the parameters you set in configuration mode on menu
levels 1 to 4 to the default settings:
➤
Start configuration mode (see chapter “Start and end configuration
mode” on page 31).
✓
The first digit of the display (fig.
e
5, page 6) shows the menu level
and the second and third show the parameter which can be set.
➤
Press the
+
button (fig.
e
6, page 6) four times to switch to menu
level 5.
✓
The digital display shows
00
.
➤
Press the
Mode
button (fig.
e
4, page 6) to return the system to its
default settings.
✓
The digits in the display
00
flash.
➤
Press the
+
button.
✓
The digital display shows
01
.
➤
Press the
Mode
button (fig.
e
4, page 6) to confirm your entry.
✓
The parameters set in configuration mode are returned to the default setting.
✓
You are now in menu level 5 and can use the
+
and
–
buttons to switch
between menu levels.
_IA_CA1000.book Seite 33 Freitag, 30. Januar 2009 11:12 11