E.  “FAN” - Fan Mode

In 

FAN

 mode there are (4) fan speed selections:

LOW: 

The fan operates continuously at low speed.

MED: 

The fan operates continuously at medium speed.

HIGH: 

The fan operates continuously at high speed.

AUTO: 

The fan will be OFF.

F.  

“FURN” / “AQUA” - Furnace Or Aqua (Hydronic) Heating Mode

(Factory setting is “

FURN

”)

To change the setting from “FURN” to “AQUA” or vice versa, simultaneously press 
the 

 and 

 buttons. The LED will display the selected option.

In the 

FURN

 / 

AQUA

 mode the system will cycle the RV’s furnace/aqua ON and 

OFF based on the room air temperature and the temperature set-point on the CCC 2 
thermostat. The system can be con

fi

 gured to operate using an ON/OFF differential 

of either 1 °F / °C or 2 °F / °C. This feature is programmed during the system ini-
tialization. See section, “B. System Con

fi

 guration & Initialization” on page (3).

To set the 1 °F / °C differential, simultaneously press the 

PROGRAM

 button and the 

 button (“dIF1” will appear in the display while the buttons are pressed). To set the 

2 °F / °C differential, simultaneously press the 

PROGRAM

 button and the 

 button 

(“dIF2” will appear in the display while the buttons are pressed). In this mode there 
are (4) fan speed selections:

LOW: 

The fan operates continuously at low speed.

MED: 

The fan operates continuously at medium speed.

HIGH: 

The fan operates continuously at high speed.

AUTO: 

The fan is OFF.

G.  “AUTO” - Auto Change Over Mode

In the 

AUTO

 mode the system will automatically change the mode of operation from 

cool to heat or from heat to cool. In order for this mode to operate, the zone being 
programmed must contain either a heat pump, heat strip or furnace heating source. 
When in the 

AUTO

 mode, all pre-programmed operations for the heat pump, heat 

strip, and furnace will apply.

Auto Change Over Cooling: 

If the room temperature rises above the temperature 

set-point by 2 °F / °C, the air conditioner will turn ON until the room temperature 
reaches the temperature set-point at which time the air conditioner will cycle OFF.

Auto Change Over Heating: 

If the room temperature goes below the temperature 

set-point by 2 °F / °C, the available heat source will be cycled ON until the room 
temperature reaches the temperature set point at which time it will cycle OFF.
If more than one heat source is available on this zone, the priority for selecting the 
heat source will be heat pump (

fi

 rst), furnace (second), and heat strip (third).

MODE DESCRIPTION

13

SPECIAL FEATURES

A.  

Auto Fan

When “AUTO” fan is selected, the fan speed will vary depending on the difference 
between the temperature set-point and the room temperature. In “AUTO” fan, the 
compressor and fan will cycle ON and OFF with the thermostat.
When the difference is:
8 °F / °C or more 

The fan operates on HIGH

5 to 7 °F / °C 

The fan operates on MED

4 °F / °C or less 

The fan operates on LOW

B.  

Zone Control

Zones are established at the time of the installation of your Dometic CCC 2 thermo-
stat. A zone is an area of cooling/heating which is controlled independently by the 
CCC 2 thermostat. The CCC 2 thermostat allows for four zones (Air Conditioner/
Heat Pump) to be set up and run independent of each other. If you have one air 
conditioner/heat pump installed, you will have one zone. If your RV has more than 
one cooling/heating system, you may have two, three, or four zones. 
Your CCC 2 thermostat will operate cooling and heating appliances that your vehicle 
manufacturer has designed to cool or heat speci

fi

 c areas (zones) of your RV. The 

CCC 2 thermostat will advise you of the number of zones in your RV. The zones are 
displayed “1”, “2”, “3”, or “4” in the LCD readout. See section, “D. Quick Reference 
To LCD Icons” on page (5).
In the event your vehicle has multiple zones designed, you have the freedom of 
selecting different modes of operations for each zone. To change from one zone to 
another, press the 

ZONE

 button on the CCC 2 thermostat. Each time the button is 

pressed and released the indicator will change the zone data displayed. When the 
zones have been programmed, the zones in operation will be displayed. To program 
each zone, simply repeat the programming steps shown under main heading, “Pro-
gramming & Operations” on page (6). 

C.  Dehumidify (Select Models)

The Dometic CCC 2 thermostat will accommodate only one dehumidify air con-
ditioner within the four zones. The dehumidify air conditioner can either be zone 
“1”, “2”, “3”, or “4”. The dehumidify air conditioner must have the 

DEHUMIDIFY

 dip 

switch set to the “ON” position when the unit is installed.
When the relative humidity is above the humidity set-point the compressor will cycle 
ON and if the fan is set to “AUTO,” it will run on “LOW” speed. If “LOW,” “MED,” or 
“HIGH” speed is selected, the fan will run in the speed selected. When the humidity 
is 5% or less than the humidity set-point the compressor will cycle OFF.

Summary of Contents for 3314080 Series

Page 1: ...N N3T 5L8 CANADA 519 720 9578 For Service Center Assistance Call 800 544 4881 COMFORT CONTROL CENTER 2 THERMOSTAT OPERATING INSTRUCTIONS REVISION Form No 3314149 018 10 11 Replaces 3314149 000 French 3314169 016 2011 Dometic LLC LaGrange IN 46761 PROGRAMMABLE THERMOSTAT MODEL 3314081 XXX WITH DEHUMIDIFY 3314080 XXX WITH OUT DEHUMIDIFY ...

Page 2: ... 13 B Zone Control 13 C Dehumidify Select Models 13 D Program 1 2 14 E Examples Of Times Programmed 16 F CANbus Interface 16 G Auxiliary Heat Heat Pump Models Only 17 H Stage Select Two Air Conditioner Heat Pump Units Select Models On One Zone 17 I Stage Select Dual Compressor Air Conditioner Heat Pump Select Models 17 J Auto Generator Start AGS 18 K Load Shed 18 L Defrost Cycle Heat Pump Models O...

Page 3: ...tat review the following diagrams and accompanying text that explain the functional characteris tics of this system Your CCC 2 thermostat is equipped with a liquid crystal display LCD that identifies the mode of operation OFF Cool Heat Pump Fan Heat Strip Auto Furnace or Aqua temperature set point zone identification 1 2 3 4 fan speed Auto Low Med High program 1 and 2 inside temperature clock F C ...

Page 4: ... or replacement of the air conditioner heat pump air fil ters is required NEVER run the air conditioner without the air filter in place This may plug the unit evaporator coil with dirt and may substantially degrade the perfor mance of the unit over time When a system fan run time exceeds 1000 hours the filter icon is displayed in the LCD See section D Quick Reference To LCD Icons on page 5 When th...

Page 5: ...art on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature For a more permanent solution to high heat gain accessories like Dometic outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy company during the cool of the evening B Disclaimer The manufacturer of this air conditioner ...

Page 6: ...shut down E1 Loss of communication between the CCC 2 thermostat and an individual system power module board The LED will display error code E1 and the zone number that lost communication Any additional zones that loose communication will blink in addition to the current zone E2 Open circuit or out of range indoor temperature sensor All heat cool and dehu midify operations will be locked out Manual...

Page 7: ...ontacts or an off board relay from the RV power management system When the Load Shed signal is detected the compres sor shall turn OFF L Defrost Cycle Heat Pump Models Only To avoid frost formation on the outside coil and to obtain maximum performance when the outside temperature is less than 42 F 6 C and greater than 30 F 1 C a defrost cycle will be initiated While operating in this temperature r...

Page 8: ...signated secondary the power module board DIP switch identified as Ext Stage must be set to the ON position in order to configure the power module board for the on demand secondary stage operation in this example Zone 2 and Ext Stage DIP switches are in the ON position In this stage configuration the CCC 2 thermostat temperature set point will be used for both the primary and the secondary stage a...

Page 9: ... will be Auto LOW MED and HIGH The fan will run continuously during LOW MED and HIGH fan settings The fan will cycle ON and OFF with the thermostat on AUTO setting For more information on auto fan see section A Auto Fan on page 13 H Temperature Set Point Press the or button to change the temperature set point The temperature set point is indicated by 2 digits on the LCD Press the button to increas...

Page 10: ... on the room air temperature and the temperature set point on the CCC 2 thermostat When the system calls for cooling there will be a delay of approximately 2 minutes During this delay the hour glass icon will be displayed in the LCD In auto fan the fan will turn ON first followed by the compressor in approximately 15 seconds In this mode there are 4 fan speed selections LOW The fan operates contin...

Page 11: ...n immediately SPECIAL FEATURES 11 HIGH The fan operates continuously at high speed The compressor cycles ON and OFF AUTO When auto fan is selected the fan speed will vary depending on the differ ence between the temperature set point and the room temperature In auto fan the compressor and the fan will cycle ON and OFF with the thermostat The compressor shuts OFF first followed by the fan in approx...

Page 12: ...he priority for selecting the heat source will be heat pump first furnace second and heat strip third MODE DESCRIPTION 13 SPECIAL FEATURES A Auto Fan When AUTO fan is selected the fan speed will vary depending on the difference between the temperature set point and the room temperature In AUTO fan the compressor and fan will cycle ON and OFF with the thermostat When the difference is 8 F C or more...