Domestia DML-004-003 User Manual Download Page 8

 

5.

 

ERROR CODES  

Functioning normally: 
The LED associated to the output channel is lit continually when activated, and off when it is inactive. In case 
of malfunction, the table below gives a series of error codes. 

STATUS 

Problem 

Possible Causes  

The LEDs 1 to 4 lights up in 
sequence. 

Impossible to control the 
lights. 

Verify the connections to the bus RS485 (connection 
between the DML-004-003 and the master module) 

LEDs 1, 2, 3 or 4 blink 
(simultaneously) every 
second. 

Overheating of the channels: 
the thermal protection was 
activated. 

- The connected element is too powerful. 
- The surrounding temperature is too high.   
- The selected dimming mode is not appropriate.  

LEDs 1, 2, 3 or 4 blink 
rapidly (2 times/ second). 

Short-circuit or overload. 

- The output is in short-circuit. 
- The connected element is much too powerful. 
- The connected element is not configured correctly 
(See the configuration for the « Dimming mode »  

THE LEDs function 
normally. 

The lights will not turn on. 

- Verify the connections of the lights. 
- The outputs are not programmed in mode relay (C 
+ E) (in the case of a master module DMC-012-002). 

6.

 

TECHNICAL CHARACTERISTICS 

Functional characteristics  

 

LED dimmable 230V : 3W à 150W 

 

Incandescent and Halogen 230V : 5 W à 250 W 

 

Halogen Very Low Voltage lamps via electromagnetic transformer : 20VA à 250 VA 

               

The transformer should not be used at less than 75% of its capacity.

 

 

Halogen Very Low Voltage lamps via electromagnetic transformer : 25VA à 250 VA 

We have to take into account the performance of the transformers to calculate the maximum number 
of lights. 

Electrical Characteristics  

 

Power supply : 230 VAC / 50Hz 

 

Consumption free of polarity: 2,60 W 

 

Non-replaceable internal fuse  

Temperature range  

 

Stocking : -30°C à + 65°C 

 

Fonctioning : -10°C à +45°C

 

CE  marking

This  product  complies  with  all  applicable  directives.  The  EU  Declaration  of  Conformity  is 

available on www.domestia.be 

7.

 

WARRANTIES 

The basic duration of your product’s warranty is 2 years from the receipt of your order. Whatever the problem 
you have with your product, keep carefully your invoice bearing the serial number(s), because it is the only 
document acting as a guarantee. 
Excluded from this warranty are the following cases: 

 

 

Damage  caused  by  inappropriate  use,  improper  use,  poor  maintenance  or  failure  to  respect  the 
instructions given by the manufacturer in this user manual.  

 

Repair attempts made by the customer or a third party which are not permitted 

 

Damage  caused  by  accident,  force majeure  or other  causes  for which  Domestia  cannot  be  held 
responsible 

 

Fault not affecting the proper functioning or proper use of the equipment.      

         

 

Domestia 
176, rue Jean-Jaurès 
4430 Ans 
Tél : 04/ 372 07 16 
Fax : 04/ 372 07 19 
[email protected] 
www.domestia.be 

Summary of Contents for DML-004-003

Page 1: ...1...

Page 2: ...he maximum power allowed in function of the type of variable load 1 The Phase outputs to lamp circuits 2 phase terminals per output 2 Working indicators 1 by output 3 Dip switch for setting the dimmin...

Page 3: ...behind A relay output module DMC DKS 012 00x A relay output module DMC DKS 008 001 A master control module DME LAN Wiring example Note The output terminals are doubled The two terminals correspond to...

Page 4: ...the older master modules DMC012 002 DME LAN 001 the module can be addressed via the addressing button 1 Press during 4 seconds on the addressing button till the blue LED goes off 2 Then press as many...

Page 5: ...tton is pressed 3 4 Configuration of the type of lighting element s and the minimum level of intensity 3 4 1 Configuration from the application Domestia Home Manager When this module is connected to a...

Page 6: ...mode Trailing or Leading Edge Leading Edge Triac Mode OBLIGATORY for all inductive loads Trailing Edge Reverse mode Most current lamps work best in this mode The DIP SWITCH allows you to adapt the fu...

Page 7: ...ess on the CENTER key again to leave this output s programmation 4 OPERATION 4 1 Working in slave mode As long as a pushbutton PB is pressed the associated output will be dimmed A short press on the P...

Page 8: ...via electromagnetic transformer 20VA 250 VA The transformer should not be used at less than 75 of its capacity Halogen Very Low Voltage lamps via electromagnetic transformer 25VA 250 VA We have to tak...

Reviews: