b.

 

Trailing Edge (Reverse mode) 

PROHIBITED for all inductive loads (ex: electromagnetic 

transformer)

 

 

The « Mode » which will give the best result depends on the type of LIGHTBULBs used. 

 

2-

 

With the "Minimum" potentiometer you can choose the lighting value when the gradation 
level is at minimum. The minimum setting depends on the lamp models used, their number 
and  the dimming Mode (Leading edge or Trialing edge). The dimmer’s  ouptut is lit at the 
minimum level to visualize the actual setting. 

 

Do not select a minimum intensity that’s too close to the minimum tolerated by the lamps 

=> 

The voltage of the electrical network may change over time and the lamps may not light up 
or they may flicker at a low ignition level. 

 

3-

 

The "Curve" changes the way the current changes as a function of the dimming percentage. 
Generally the curve "Exponential 1" is the best choice. 

4-

 

Indicates the temperature of the output heatsink. 

3.4.2

 

Configuration from the module’s setting button (BP Settings) 

 

DML-004-003 module is designed to work with different variable types of loads. The configuration must be 
adapted in function of the type of load. 

DOMESTIA DOES NOT GUARANTY THAT ALL “LED” MODELS WILL FUCTION CORRECTLY:

 For more informations, 

contact your LED lamp dealer. 
 

A)

 

Setting of the dimming mode

 (

Trailing

 or 

Leading Edge

 

Leading Edge = « Triac » Mode

 OBLIGATORY for all inductive loads

 

Trailing Edge = « Reverse mode ».

 

Most current lamps work best in this mode.    

 

The DIP SWITCH allows you to adapt the function mode of each output individually. The “dip 
switch” will be placed either in its original position (OFF), or in position (ON). 

 

In case of inductive load the DIP SWITCH must obligatory be placed in its original position, 
OFF (downwards) => 

Leading Edge 

Mode 

 

For the other types of loads a test run is the best way to determine the correct setting. Some lamps will work 
as well in one mode as in the other.  
The « Trailing Edge » mode (Dip Switch in position ON => upward) generally generates less heating

Note: The setting must be made when the module is powered. 
 

B)

 

Setting of the minimum intensity level 

 

1-

 

Make a long Press on the « BP Settings » till the corresponding blue LED goes off (4 seconds). 
 

2-

 

Select the channel to be set by short presses on the « BP Settings ».  The flashing LED moves with each 
press. 

 

3-

 

Make a long press the « BP Settings » to activate the selected channel in the setting mode. The LED 
lights up permanently and the channel lights up at the minimum level. 

 

4-

 

Set the minimum level by briefly pressing the « BP Settings » => The set level is directly adjusted to the 
selected output. 20 settings levels are possible. 

 

5-

 

To return to the channel selection for setting (step 2) make a long press on the « BP Settings ». 
 

6-

 

To leave the setting mode press the « BP Adress ». 

1 2 3 4

ON  DIP

Summary of Contents for DML-004-003

Page 1: ...1...

Page 2: ...he maximum power allowed in function of the type of variable load 1 The Phase outputs to lamp circuits 2 phase terminals per output 2 Working indicators 1 by output 3 Dip switch for setting the dimmin...

Page 3: ...behind A relay output module DMC DKS 012 00x A relay output module DMC DKS 008 001 A master control module DME LAN Wiring example Note The output terminals are doubled The two terminals correspond to...

Page 4: ...the older master modules DMC012 002 DME LAN 001 the module can be addressed via the addressing button 1 Press during 4 seconds on the addressing button till the blue LED goes off 2 Then press as many...

Page 5: ...tton is pressed 3 4 Configuration of the type of lighting element s and the minimum level of intensity 3 4 1 Configuration from the application Domestia Home Manager When this module is connected to a...

Page 6: ...mode Trailing or Leading Edge Leading Edge Triac Mode OBLIGATORY for all inductive loads Trailing Edge Reverse mode Most current lamps work best in this mode The DIP SWITCH allows you to adapt the fu...

Page 7: ...ess on the CENTER key again to leave this output s programmation 4 OPERATION 4 1 Working in slave mode As long as a pushbutton PB is pressed the associated output will be dimmed A short press on the P...

Page 8: ...via electromagnetic transformer 20VA 250 VA The transformer should not be used at less than 75 of its capacity Halogen Very Low Voltage lamps via electromagnetic transformer 25VA 250 VA We have to tak...

Reviews: