b.
Trailing Edge (Reverse mode)
PROHIBITED for all inductive loads (ex: electromagnetic
transformer)
The « Mode » which will give the best result depends on the type of LIGHTBULBs used.
2-
With the "Minimum" potentiometer you can choose the lighting value when the gradation
level is at minimum. The minimum setting depends on the lamp models used, their number
and the dimming Mode (Leading edge or Trialing edge). The dimmer’s ouptut is lit at the
minimum level to visualize the actual setting.
Do not select a minimum intensity that’s too close to the minimum tolerated by the lamps
=>
The voltage of the electrical network may change over time and the lamps may not light up
or they may flicker at a low ignition level.
3-
The "Curve" changes the way the current changes as a function of the dimming percentage.
Generally the curve "Exponential 1" is the best choice.
4-
Indicates the temperature of the output heatsink.
3.4.2
Configuration from the module’s setting button (BP Settings)
DML-004-003 module is designed to work with different variable types of loads. The configuration must be
adapted in function of the type of load.
DOMESTIA DOES NOT GUARANTY THAT ALL “LED” MODELS WILL FUCTION CORRECTLY:
For more informations,
contact your LED lamp dealer.
A)
Setting of the dimming mode
(
Trailing
or
Leading Edge
)
Leading Edge = « Triac » Mode
OBLIGATORY for all inductive loads
Trailing Edge = « Reverse mode ».
Most current lamps work best in this mode.
The DIP SWITCH allows you to adapt the function mode of each output individually. The “dip
switch” will be placed either in its original position (OFF), or in position (ON).
In case of inductive load the DIP SWITCH must obligatory be placed in its original position,
OFF (downwards) =>
Leading Edge
Mode
For the other types of loads a test run is the best way to determine the correct setting. Some lamps will work
as well in one mode as in the other.
The « Trailing Edge » mode (Dip Switch in position ON => upward) generally generates less heating
.
Note: The setting must be made when the module is powered.
B)
Setting of the minimum intensity level
1-
Make a long Press on the « BP Settings » till the corresponding blue LED goes off (4 seconds).
2-
Select the channel to be set by short presses on the « BP Settings ». The flashing LED moves with each
press.
3-
Make a long press the « BP Settings » to activate the selected channel in the setting mode. The LED
lights up permanently and the channel lights up at the minimum level.
4-
Set the minimum level by briefly pressing the « BP Settings » => The set level is directly adjusted to the
selected output. 20 settings levels are possible.
5-
To return to the channel selection for setting (step 2) make a long press on the « BP Settings ».
6-
To leave the setting mode press the « BP Adress ».