Domestia DML-004-003 User Manual Download Page 4

 

 

3.

 

CONFIGURATION 

 

3.1

 

Addressing from the application “Domestia 

Home Manager” (via the master module) 

 

When the module is connected to the master module of the type 

DMC-

008-001 

(from the firmware V1.28), 

DMC-012-003

 or 

DME-LAN-002

 (from the 

firmware  V3.0)  module 

DML-004-003

  can  be  addressed  from  our 

programmation app.  « Domestia Home Manager ».  

1)

 

Automatical addressing: Click on « Add automatically », it scans the 
RS485  bus  and  recognizes  the  connected  modules.  Then  it  is  still 
possible to modify the module’s address thanks to the arrows

 

« up » 

and « down ». 

2)

 

Half-automatical addressing: click on “Add half-automatically» then 
press the addressing button

 

of the module(s) DML-004-003 to add. 

Click  again  on  «Add  half-automatically»  to  end  the  process  of 
adding modules. 

3.2

 

Manual addressing 

To make the DML-004-003 compatible with the older master modules 
(DMC012-002, DME-LAN-001) the module can be addressed via the 
addressing button.  

 

1)

 

Press during 4 seconds on the addressing button (till the blue LED 
goes off)  

2)

 

Then press as many times as the wished address requires (see 

addressing table

). The LED indicator lights up at each press. 

(max. 

delay of 2 seconds between the successive pushes) 

3)

 

After a delay of 2 seconds following the last press the blue LED 
flashes the number of times that the button has been pushed to 
confirm the address. 

 

Table d’adressage

 

Adresse du 

module

 

Plage des 

sorties

 

13-16 

17-20 

21-24 

25-28 

29-32 

33-36 

37-40 

41-44 

45-48 

10 

49-52 

11 

53-56 

12 

57-60 

13 

61-64 

14 

65-68 

15 

69-72 

16 

73-76 

17 

77-80 

18 

81-84 

19 

85-88 

20 

89-92 

21 

93-96 

22 

97-100 

23 

101-104 

24 

105-108 

25 

109-112 

26 

113-116 

27 

117-120 

28 

121-124 

29 

125-128 

30 

129-132 

31 

133-136 

32 

137-140 

33 

141-144 

34 

145-148 

35 

149-152 

36 

153-156 

37 

157-160 

38 

161-164 

39 

165-168 

40 

169-172 

41 

173-176 

42 

177-180 

43 

181-184 

44 

185-188 

45 

189-192 

Summary of Contents for DML-004-003

Page 1: ...1...

Page 2: ...he maximum power allowed in function of the type of variable load 1 The Phase outputs to lamp circuits 2 phase terminals per output 2 Working indicators 1 by output 3 Dip switch for setting the dimmin...

Page 3: ...behind A relay output module DMC DKS 012 00x A relay output module DMC DKS 008 001 A master control module DME LAN Wiring example Note The output terminals are doubled The two terminals correspond to...

Page 4: ...the older master modules DMC012 002 DME LAN 001 the module can be addressed via the addressing button 1 Press during 4 seconds on the addressing button till the blue LED goes off 2 Then press as many...

Page 5: ...tton is pressed 3 4 Configuration of the type of lighting element s and the minimum level of intensity 3 4 1 Configuration from the application Domestia Home Manager When this module is connected to a...

Page 6: ...mode Trailing or Leading Edge Leading Edge Triac Mode OBLIGATORY for all inductive loads Trailing Edge Reverse mode Most current lamps work best in this mode The DIP SWITCH allows you to adapt the fu...

Page 7: ...ess on the CENTER key again to leave this output s programmation 4 OPERATION 4 1 Working in slave mode As long as a pushbutton PB is pressed the associated output will be dimmed A short press on the P...

Page 8: ...via electromagnetic transformer 20VA 250 VA The transformer should not be used at less than 75 of its capacity Halogen Very Low Voltage lamps via electromagnetic transformer 25VA 250 VA We have to tak...

Reviews: