Page 11
Siren Advanced User Manual
Compatible Command Classes
Command Class
Notes
Device Reset Locally V1 (5A)
-
Powerlevel V1 (73)
-
Battery V1(80)
-
Association Group Information V1 (59)
-
Z-Wave Plus Info V2 (5E)
Returned Value:
01 07 00 0F 00 0F 00
Z-Wave Plus Version:
01
Role Type
: 07
(Slave Sleeping Listening)
Node Type
: 00
(Z-Wave Plus Node)
Installer Icon Type
: 0F 00
(Siren)
User Icon Type
: 0F 00
(Siren)
Version V2 (86)
Returned Value:
06 04 05 02 39 10 00
Z-Wave Library Type:
06
(Routing Slave)
Protocol Version
: 04 05
Protocol Sub-Version
: 02 39
Application Version
: 10
Application Sub-Version
: 00
Manufacturer Specific V2 (72)
Returned Value:
02 1F 03 01 02
Manufacturer ID:
02 1F
Product Type
: 03
Product ID
: 00 88
Association V2 (85)
Group 1
Group 1 is the “Lifeline” group, which can hold five members, typical
-
ly including the main Z-Wave controller. The Siren sends this group a
Notification Report and a Binary Switch Report when the siren is turned
on or off. It also sends this group a Battery Report in reponse to Battery
Get commands and a Locally Reset Notification upon local reset.
Group 2
Group 2 can hold five members, and the Siren sends a single command
to this Association Group, the Binary Switch Report, whenever the Siren
is turned on or off.
Group 3
Group 2 can hold five members, and the Siren sends a single command
to this Association Group, a Notification Report, whenever the Siren is
turned on or off.
Table 3 - Command Classes
Compatible Command Classes